FLUE EXHAUST PIPE INSTALLATION - SPECIAL APPLICATIONS
If types of flue exhaust different from the standard ones previously decribed are necessary, it is possible to
increase the concentric exhaust length Ø 100/60 or the double pipe exhaust length Ø 60, by adjusting the
electric fan speed (see paragraph "Parameters modification", page 69). The maximum obtainable fan speed
is 5800 rpm, while the maximum exhaust length is referred to the following table:
Fan speed 5800 rpm
Concentric flue exhaust pipe Ø 100/60 mm
Concentric pipe max. length 10 mt
Double pipe Ø 60 mm
Intake + exhaust max. length 35 mt
NOTE: For Ø 80 mm double pipe, only standard application is applied.