Inepro MicroTimer 2400 Manual De Uso página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Settings
Function F5, Minimum amount of start pulses
Minimum amount of start pulses which have to accepted in order to activate the MicroTimer
start pulses for 5 minutes. The value of this setting has to be at least 1. If the programmed value is higher than
1, the start pulses will be shown on the displayed until the necessary amount is reached.
Example (Function F1 is set at 5 minutes)
1
e
1
start pulse
5 minutes
e
2
start pulse
-
e
3
start pulse
-
Total time
5 minutes
Value F4
1
Value F5
1
Function F6, Service indicator 1
The maximum amount of programmable running hours before a revision service is required. This register will
count down per 1000 minutes of relay 1 activity. The value of this register represents the number x 1000
minutes, e.g. 5 = 5000 minutes. When the counter reaches zero, the "SR" message will appear on the display.
This is the standard message to indicate that a revision "service" is required. The maximum value to be
programmed is 254 (x 1000 minutes). If the value is set at 255, the service counter is out of action.
Note: The timer will keep running as usual.
Function F7, Service indicator 2
This service counter works as described in function F6 but as soon as this counter has counted down to zero
(service counter = 0), the MicroTimer
Function F8, Buzzer setting
If the setting of function P5 is "01", it is possible to activate a pause. The pause can be activated by pressing the
Start/Pause key. Relay 1, which represents the main time, shall be disconnected during the pause. Depending
on function P6 the main time is interrupted or continues. To draw the attention of the operator/user to the fact
that a pause has been created, a buzzer signal is activated.
Setting "00": Buzzer signal off
Setting "01": Buzzer signal on
Function F9, Clean Function
By means of this function it is possible to force the cleaning of a connected device. After the posted time the
®
MicroTimer
does not accept any further start signal. This blockage can be raised by pressing the internal or
external Start/Pause key for 3 seconds. To indicate the necessity of cleaning CL will appear intermittently on the
®
MicroTimer
display.
Setting "00": Clean function off
Setting "01": Clean function on.
Function FA, Standard or external start mode
Setting "00": The Microtimer can be started by pushing the Timer button or by generating a puls, which is longer
as 200 msec, on the external connection (remote button print).
Setting "01": The MicroTimer can be started by generating a pulse between the 20 and 200 msec. This setting is
dedicated for mechanical coin mechanisms.
Note: in case the coin mechanism input is selected (setting "01") then starting the timer with the Timer button is
not possible. When the timer button is selected (setting "00"), then by generating a signal on the coin
mechanism input, the pre-time can be bridged to start the main-time. (This can be done by short circuiting the
coin mechanism connection pins)
(ECOS module EM-05)
2
5 minutes
0 minutes
5 minutes
5 minutes
-
-
10 minutes
5 minutes
2
1
1
2
(ECOS module EM-06)
(ECOS module EM-06)
®
is inhibited.
(ECOS module EM-08)
(ECOS module EM-09)
®
MicroTimer
2400 Version 4.0 05-11-2007
-
www.inepro.com
3
4
0 minutes
10 minutes
-
10 minutes
2
2
-
®
. For example, 3
5
6
5 minutes
0 minutes
5 minutes
10 minutes
5 minutes
5 minutes
15 minutes
15 minutes
3
3
1
2
15

Publicidad

Tabla de contenido
loading

Productos relacionados para Inepro MicroTimer 2400

Tabla de contenido