Ingersoll Rand ARO Manual Del Usuario página 29

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Specifications
Recommended cable: 18 AWG, 300V, stranded, insulated. Maximum length: 50m (164').
47520296001_edD
External Power Supply
Vin
Vout
I out
Controller Power Requirements
V
100 mA @ 24 VDC(no load condition)
I
1 A @ 24 VDC (max load condition)
Controller I/O
I/O
Digital inputs
Digital outputs
Analog inputs
Analog Outputs
Description
Leak detection
End of stroke
Container empty
Container full
Remote batch A start
Remote batch B start
E-stop
Analog input
Description
Solenoid actuation
External alarm
Analog output
External alarm contact rated at 120 VAC / 24 VDC, 2A, resistive only.
Environmental Conditions
Operating Temperature Range
Storage Temperature Range
Maximum Relative Humidity
90 – 264 VAC
24 VDC (± 5%)
3 A
12 - 30 VDC
Rating
Qty
24 VDC
13
24 VDC
6
4 - 20 mA
2
4 - 20 mA
2
Inputs
Pump 1
Pump 2
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Outputs
Pump 1
Pump 2
Y
Y
Y
Y
Y
Y
-4 °F to 158 °F (-20 °C to 70 °C)
-22 °F to 176 °F (-30 °C to 80 °C)
90% non-condensing
EN
EN-12

Publicidad

Tabla de contenido
loading