TROUBLESHOOTING

PROBLEM: Low or No Output Voltage – Fault LED Lit
Reason
Poor contact with battery, inverter
terminals, or DC socket.
PROBLEM: No Output Voltage – No LEDs Lit
Reason
Blown fuse.
PROBLEM: Inverter Auto Shut Down – Fault LED Lit
Reason
Battery voltage is below 9.5 volts.
Inverter is too hot (thermal shut down
mode).
PROBLEM: Inverter Shut Down – Fault LED Lit
Reason
Equipment being operated draws too
much power.
10
®
Solution
Clean terminals thoroughly. Reinstall
and tighten. Clean DC socket with non-
metallic abrasive emery stick.
Solution
Check vehicle's Accessory Socket Fuse.
If the fuse is blown, replace with the
same type and rating fuse.
Solution
Charge or replace battery.
Allow inverter to cool.
Check for adequate ventilation.
Reduce the load on the inverter to
the specified TrueRated
max output.
Solution
Do not use the equipment with this
inverter; use a higher wattage inverter.