Abicor Binzel CAT2 Instructivo De Servicio página 39

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CAT2
6.1.1 CAT2 HL
6
1
Mount
2
CAT2 HL
3
Groove
Fig. 7
CAT2 HL
5
4
Feather key
5
Washer D=8.4 mm
Please observe the previous steps:
 6.1 Fastening the CAT2 to the robot on page EN-14, step 1 to step 5
1 Loosen the cylinder screw (6) and the washer (5).
NOTICE
• A feather key (4) is fixed on the mount (1). It defines the zero position of
the components with respect to the robot arm.
2 Put the feather key (4) up to the stop into the groove (3) of CAT2 HL (2).
3 Fix the mount (1) with the washer (5) and the cylinder screw (6) and using
the max. tightening torque 20 NM on CAT2 HL (2).
1
4
6
6 Putting into operation
2
3
Cylinder screw M8x16
EN - 17

Publicidad

Tabla de contenido
loading

Tabla de contenido