Before Use; Operation; Preparing For Use - Hilti TE30 Manual De Instrucciones

Ocultar thumbs Ver también para TE30:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.3.4 Work area safety
a) Ensure that the workplace is well lit.
b) Ensure that the workplace is well ventilated. Ex-
posure to dust at a poorly ventilated workplace may
result in damage to the health.
c) If the work involves breaking right through, take
en
the appropriate safety measures at the opposite
side. Parts breaking away could fall out and / or fall
down and injure other persons.

6 Before use

6.1 Fitting the side handle 2
CAUTION
Remove the depth gauge from the side handle in order
to avoid injury.
1.
Disconnect the supply cord plug from the power
outlet.
2.
Release the side handle clamping band by turning
the handle counterclockwise.

7 Operation

CAUTION
In the event of the drill bit sticking, the power tool will
pivot about its own axis. Always use the power tool with
the side handle fitted and hold it securely with both
hands so that the resulting opposing force causes
the slip clutch to release in the event of the drill bit
sticking. Use clamps or a vice to hold the workpiece
securely.
8
5.3.5 Personal protective equipment
The user and any other persons in the vicinity must
wear suitable eye protection, a hard hat, ear protec-
tion, protective gloves and breathing protection while
the tool is in use.
3.
Slide the side handle clamping band over the chuck
and onto the cylindrical section at the front end of
the power tool.
4.
Pivot the side handle into the desired position.
5.
Secure the side handle by turning the grip clockwise.
6.
Check that the clamping band is correctly located
in the groove provided.
6.2 Use of extension cords and generators or
transformers
Please refer to section 2 "Description".
6.3 Dust removal (TE DRS‑S)
A DRS dust removal head can be fitted to the depth
gauge of the side handle. Drilling dust and fragments can
then be removed by a vacuum cleaner. For further infor-
mation on operation and use of the dust removal system,
please refer to the separate operating instructions for the
TE DRS‑S.

7.1 Preparing for use

7.1.1 Adjusting the depth gauge 3
1.
Release the side handle clamping band by turning
the handle counterclockwise.
2.
Pivot the side handle into the desired position.
3.
Adjust the depth gauge to the desired drilling depth
"X".
4.
Tighten the side handle securely by turning it clock-
wise.

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Te30-avrTe30-c-avrTe30-m-avr

Tabla de contenido