STARTING UP AND PROGRAMMING
1
CONNECTION TO THE GRID
1 Connect the control board to the electricity supply:
the display should show CL.
Reset (rS): after connecting the electricity power
supply and activating any of the key devices, the
gate closes to the stopper, with the stopper being
assigned the position "gate closed".
2
DISPLAY
P24 P25
ENCODER1
ENCODER2
-FT
AUX
(Test)
24 Vdc
P13 P14 P15 P16 P17 P18 P19 P20
P21 P22 P23
P1 P2 P3
P4 P5 P6
P7 P8
P9 P10
P11 P12
D1:
Menus display
D2:
Parameters display
D3 - D4: Parameter value display
The display goes off following a long period
without pressing any key on the control
board. Press the ENTER key to reactivate.
CN22
+24Vdc
MOTOR2
G4 G5
G6
MOTOR1
G7 G8
G9 G10
N
L
G1 G2 G3
POWER - 230V
M144C
CHANGING TURNING DIRECTION: if, when
carrying out the reset (rS), any leaf opens instead of
closing, it is necessary to change the turning
direction of the corresponding operator by
programming parameter C1 (see "Initial Conditions
Programming (D1= "C")" on page 60).
During programming, ensure there is no
person or object in the radius of action of the
gate and the operation mechanisms.
Indications during operation:
D1 and D2:
CL
(static)
Gate closed
CL
(flashing)
Gate closing
OP
(static)
Gate open
OP
(flashing)
Gate opening
PC
(static)
Pedestrian gate closed
PC
(flashing)
Pedestrian gate closing
PO
(static)
Pedestrian gate open
PO
(flashing)
Pedestrian gate opening
XX
(countdown)
Gate on standby
StOP
STOP pushbutton open
PA
(static)
Pause (operation not complete)
rS
(static)
Gate searching for close position
HP.
(static)
Dead man function
D3 and D4:
C4
Interior safety device activated
C5
Exterior safety device activated
C9
Mechanical or resistive strip activated
E1
Encoder motor 1 shutdown
E2
Encoder motor 2 shutdown
F1
Motor 1 thrust limit exceeded
F2
Motor 2 thrust limit exceeded
Indications during programming
D1 (Menus): Shows the selected menu. The following
menus are available:
C
Prior Conditions menu
P
Programming menu
F
Main Functions menu
A
Advanced Functions menu
ç
Operation Counter
D2 (Parameters):
Shows each parameter of the selected D1 menu.
D3 - D4 (Parameter Values):
Shows the value or option of the selected D2
parameter.
English
59
VIVO-D201 Control board