ELECTRICAL CONNECTIONS

Complete the installation in line with low voltage regulations and applicable rules.
Use cables with sufficient section, always earthed.
Check the manufacturer's instructions for all the elements installed.
Power supply and operator connections
Connect a direct current ERREKA operator
(24Vdc). Connecting a different direct current
operator to ERREKA operators may produce
incorrect operation, and may lead to accidents
and failures due to the thrust limiter of the
control board not working properly.
IZAR Operator
O
IZAR operator: ensure the limit switches are
correctly connected. If they are not, the
motor will continue to operate until wheel A
or B reaches the stopper, thus breaking the
mechanism.
O
This type of operator does not need capacitors
for operation.
VCD
Vcd geared motor connection
VCD
Vcd geared motor connection
FCMA A operation limit switch connection
COM
Limit switch common connection
FCMB B operation limit switch connection
FCA
Opening limit switch connection
FCC
Closing limit switch connection
The connection of the limit switches depends on
each particular installation: in some installations
FCMA will coincide with FCA and FCMB with
FCC, whilst in others it will be the other way
round. Verification is done by testing.
INSTALLATION
DIP1
DIP2
DIP3
DIP4
VIVO-D103 / ADB30 Control board