ELECTRICAL CONNECTIONS

Complete the installation in line with low voltage regulations and applicable rules.
Use cables with sufficient section, always earthed.
Check the manufacturer's instructions for all the elements installed.
O
These operators REQUIRE capacitors for operation.
O
The operating voltage of the operators and the control board must coincide with the mains voltage
(230VAC-50Hz for the VIVO-M203; 125VAC-60Hz for the VIVO-M203M).
Brake connections
If the operator is fitted with a brake connected internally to the motor (for example, ORION
operators), it is not necessary to connect the brakes, although slowdown should be cancelled
(select CA00).
If the operator is fitted with a brake for independent connection (for example, CICLON or
MAGIC operators), the EPS1 card should be used as shown in this diagram, selecting
parameter Ab01.
FR1
FR2
The EPS1 card can be used for other functions; check the programming table "Advanced
Functions Programming (D1= "A")" on page 85.
M203: 230V/50Hz
COM
F1
L1
L2
DL1: Red LED, FR1 activation
DL2: Green LED, FR2 activation
EPS1
P241Z5
Control board VIVO-M203(M)