The meter is designed to withstand the stated max voltages. If it
is not possible to exclude without that impulses, transients,
disturbance or for other reasons, these voltages are exceeded
a suitable prescale (10:1) must be used.
*
Replace a defective fuse only with a fuse of the original rating.
Never short-circuit fuse or fuse holding.
*
Disconnect test leads or probe from the measuring circuit
before switching modes or functions.
*
Do not conduct voltage measurements with the test leads
connected to the mA/A- and COM-terminal of the equipment.
*
The 10A-range is protected. To avoid damage or injury, use the
meter only in circuits limited by fuse or circuit breaker to 10A or
2000VA.
*
To avoid electric shock, disconnect power to the unit under test
and discharge all capacitors before taking any resistance
measurements.
*
Do not conduct current measurements with the leads connected
to the V/Ω-terminals of the equipment.
*
Check test leads and probes for faulty insulation or bare wires
before connection to the equipment.
*
To avoid electric shock, do not operate this product in wet or
damp conditions. Conduct measuring works only in dry clothing
and rubber shoes, i. e. on isolating mats.
*
Never touch the tips of the test leads or probe.
*
Comply with the warning labels and other info on the
equipment.
*
Always start with the highest measuring range when measuring
unknown values.
*
Do not subject the equipment to direct sunlight or extreme
temperatures, humidity or dampness.
*
Do not subject the equipment to shocks or strong vibrations.
*
Do not operate the equipment near strong magnetic fields
(motors, transformers etc.).
*
Keep hot soldering irons or guns away from the equipment.
*
Allow the equipment to stabilize at room temperature before
taking up measurement (important for exact measurements).
*
Do not input values over the maximum range of each
measurement to avoid damages of the meter.