5
Technical Data
Temperature specifications D2C D
Permissible ambient temperature:
D2C W
Permissible ambient temperature:
Permissible storage temperature:
Material specifications / chemical resistance
Part
Housing and frame D2C D
Housing D2C W
Rear panel D2C D
Membrane keypad
Seal
Inner seal, D2C D
Retaining bracket and screws
M5 screws
Chemical resistance:
The device is resistant to normal atmospheres in installation rooms.
Dimensions and weights
D2C D
96 x 96 mm in accordance with DIN 43700, depth 140 mm
Device weight without packing:
Gross weight of device with packing: approx. 1200 g
D2C W
198 x 200 x 76 mm
198 x 200 x 35 mm
198 x 200 x 38 mm
Device weight without packing:
Net weight of device with packing: approx. 2.0 kg
Electrical data
Rated voltage:
Maximum current intake:
Internal fuse protection with:
Rated voltage:
Maximum current consumption:
Internal fuse protection with:
30
Material
PPO GF 10
PPE GF 10
PPE GF 20
Polyester film PET
Cellular rubber CR
Silicon-based sealing compound
Galvanised, zinc-plated steel
A2
approx. 850 g
(W x H x D) Wall mounting
(W x H x D) Control panel installation, external
(W x H x D) Control panel installation, internal
approx. 1.2 kg
230 VAC (180-254 VAC) / 115 VAC (90-127 VAC), 50/60 Hz
100 mA at 115 V
50 mA at 230 V
5 x 20 mm miniature fuse
160 mA, 250 V slow-blow
24 V DC or 24 V AC, 50/60 Hz
(operation with safety extra-low voltage only!)
250 mA at 24 V
5 x 20 mm miniature fuse
500 mA, 250 V slow-blow
Control panel
installation
0 °C...45 °C
-5 °C...40 °C
-10 °C...70 °C
Wall mounting
-5 °C...40 °C