4.3
Parameter menu
Code
No.
Name
Password entry
C00
Setpoint source
C01
Load Lenze setting
C02
Configuration -
CE1
Digital Input E1
Configuration -
CE2
Digital Input E2
Configuration -
CE3
Digital Input E3
Lenze 13435747 EDBSX03 v17 EN, DE, FR, IT, ES
Possible Settings
Selection
Lenze
0
0
0
Analog input (terminal 8; see C34)
1
Code c40
0
No action/loading complete
1
Load 50 Hz Lenze settings
2
Load 60 Hz Lenze settings
3
Load OEM settings
4
Translate
WARNING!
C02 = 1... 3 overwrites all settings! TRIP circuitry may be disabled!
Check codes CE1...CE3.
NOTE
If an EPM that contains data from a previous software version is installed, C02 =
4 converts the data to the current version.
1
1
Activate fixed setpoint 1 (JOG1)
2
Activate fixed setpoint 2 (JOG2)
3
DC braking (DCB)
4
Direction of rotation
5
Quick stop
6
CW rotation
7
CCW rotation
4
8
UP (setpoint ramp-up)
9
DOWN (setpoint ramp-down)
10 TRIP set
3
11 TRIP reset
12 Accel/decel 2
13 Deactivate PI
14 Activate fixed PI setpoint 1
15 Activate fixed PI setpoint 2
NOTE
CFG
A
fault will occur under the following conditions:
• E1...E3 settings are duplicated (each setting can only be used once)
• One input is set to UP and another is not set to DOWN, or vice-versa
Commissioning
999
Visible only when password is active
(see C94)
Observe notes about c40
• C02 = 1... 4 only possible with
• C02 = 2 : C11, C15 = 60 Hz
• Use C37...C39 to adjust fixed setpoints
• Activate JOG3: Both terminals = HIGH
See also C36
LOW = CW rotation
HIGH = CCW rotation
Controlled deceleration to standstill,
active LOW; Set decel rate in C13 or
c03
CW rotation = LOW and CCW rotation =
LOW: Quick stop; Open-circuit protected
UP = LOW and DOWN = LOW: Quick
stop; Use momentary NC contacts
Active LOW, triggers
to standstill)
NOTE: NC thermal contact from the
motor can be used to trigger this input
See also c70
See c01 and c03
Disables PI function for manual control
• Use C37...C39 to adjust fixed
setpoints
• Activate fixed PI setpoint 3: Both
terminals = HIGH
IMPORTANT
OFF
EEr
(motor coasts
13