Pahlen Jet Swim Motion Manual De Usuario página 12

Ocultar thumbs Ver también para Jet Swim Motion:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Jet Swim Motion
Installation for fiberglass pool
This requires both the mounting kit for thin pool wall and fiberglass pool. The supplied
screws are intended for mounting in pool walls of thickness 6  –   2 0 mm.
NOTE! Jet Swim Motion must be mounted on a flat, vertical wall surface.
Figure example: fiberglass pool
1. Niche
2. Countersunk screw M5x25 (6 pcs)
3. —
4. —
5. —
6. —
7. Clamping ring
8. Screw M5x20 (8 pcs)
9. Intake grate
10. Countersunk screw M5x35 (4 pcs)
11. Front
12. Countersunk screw M5x35 (2 pcs)
13. Poolstomme
14. —
15. —
16. Support ring * with threaded holes
17. Gasket * Ø284 mm, t = 3 mm
18. Cover plate *
* Included in fiberglass pool assembly kit.
1. Make a Ø258 mm hole in the pool wall.
Align the enclosure of Fig. 1, use the enclosure as a template for the six Ø5 holes (see B Fig. 1).
2. The walls of the holes must be sealed with a thermoset resin.
3. Smooth an even layer of silicone, about 2 mm thick around the hole and on the side of the gasket (item 17) that should lie
against the pool wall. Apply silicone in the boreholes as well. Place the enclosure in the pool wall with the gasket between the
back of the enclosure flange and the pool wall. Screw the enclosure with the enclosed screws (item 2) into the support ring
(item 16) placed against the outside of the pool wall.
4. Screw the clamp ring (item 7) to the enclosure (the supplied gaskets with the base for mounting in a thin pool wall can be
omitted here) with 5 Nm in tightening torque. The screws must be greased.
5. Mount the intake grille (item 9) and the stainless-steel front. (These screws must be greased.)
6. Connect the hose for air mixing and tighten the hose clamp.
Attach the other hose orifice 100 mm above the water surface behind the pool wall, see the figure example under "Dimensions".
7. Connect the starter hose (with a loop at least 150 mm above the water surface) to the control box.
8. Connect pipes and valves to the pump, see the figure example "Wooden frame with liner". The threads must be sealed with
thread tape.
9. Electrical connection must be carried out by a qualified electrical installer.
12
ENGLISH
UP
A
Figure. 1
Niche as seen from the front.
B
(6x)
A
Surfac
E
The to
part o
Box 728, SE-194 27 Uppl
Phone +46 8 59411050, F

Publicidad

Tabla de contenido
loading

Tabla de contenido