PROBLEMS AND CAUSES

PROBLEM
1. The machine does not run.
2. The mixer does not function.
3. Cold pilot light does not light even when
turning on the right switch.
4. Compressor does not start:
4.1 There is no current.
4.2 There is current.
5. Machine does not cool at all.
6. Tap leaks.
7. Tank leaks.
- 18_EN-
U s e r ' s i n s t r u c t i o n s a n d m a i n t e n a n c e m a n u a l
CAUSE
1.1.-Mains connection is not correct.
1.2.-No current at the connection plug.
1.3.-Defective power cable.
1.4.-General switch is broken.
1.5.-Defective faston connectors for the general switch.
2.1.-Defective motor connection.
2.2.-Defective mixer switch.
2.3.-Paddle motor or paddles blocked.
2.4.-Defective motor reducer.
3.1.-Switch for this mixer is disconnected.
3.2.-Pilot light is burned out.
3.3.-Electronic thermostat defective or disconnected.
3.4.-Electronic thermostat transformer defective or disconnected.
4.1.1.-Electronic thermostat transformer defective or disconnected.
4.1.2.-Electronic thermostat defective or disconnected.
4.2.2.-Starter relay.
4.2.3.-Breaker for overheating.
4.2.4.-Compressor.
5.1.-Coolant gas leak.
5.2.-Dirty condenser.
5.3.-Insufficient ventilation around the machine.
5.4.-Broken fan motor.
5.5.-Electronic thermostat defective or disconnected.
5.6.-Cold switch is defective or on Setting zero.
6.1.-Rubber tube defective or not properly fitted.
6.2.-Check tap springs.
7.1.-Defective tank seal.