6. Dipstick insertion and oil level check
Use a screwdriver or similar tool to remove the plastic
cap on the lower part of the cylinder (Fig. 3).
Plastic cap
Insert the accessory dipstick all the way to the bottom.
Remove the dipstick and make sure the oil level is
within the range of the dipstick notches (Fig. 4).
When the oil volume is insufficient, refer to the section
"Oil change-oil topping off" on page 11 for a descrip-
tion of how to supply the oil.
7. Air coupler installation
Screw in the air coupler to the joint (Refer to Fig. 1
and Fig. 5.). The screw size of the joint is 3/8". Use an
air coupler which has the same screw size.

OPERATION

1. Start up
Insert the plug into the receptacle and start the
compressor by turning the knob of the pressure
switch, to "AUTO". (Refer to Fig. 1 and Fig. 5).
WARNING:
Do not stop or start the compressor
by use of the plug. Always use
"AUTO/OFF" knob located on the
pressure switch.
Cylinder
Fig. 3
Dipstick
MAX.
MIN.
Fig. 4
The operation of the compressor is automatic and is
controlled by the pressure switch which stops it when
the pressure in the air-tank reaches the maximum
level and restart it when the air pressure drops during
use to the restart level.
The motor of the compressor is fitted with a thermal
protection inside-the wrap, which stops the
compressor when the temperature is too high. Should
this be tripped, the compressor will restart automati-
cally after 15–20 minutes.
2. Adjustment of working pressure
Unlock the knob of the pressure reducer pulling it up,
adjust the pressure to the required level by turning the
knob clockwise to increase and counterclockwise to
decrease.
A pressure gauge is provided to know when the
required pressure is reached, lock the knob by
pushing it down firmly (Fig. 5).
WARNING:
Check the manufacturer's maximum
pressure rating for nailers, staplers
and accessories. Compressor outlet
pressure must be regulated so as to
never exceed the maximum pressure
rating of the nailers, staplers and
accessories.
Knob of the pressure switch
3. Shutdown
(1) Turn the knob of the pressure switch to "OFF". (Fig. 1)
(2) Unplug the plug from power source.
(3) Open the drain cock located at the lower part of
the tank (Fig. 6).
Drain cock
— 10 —
Knob of the pressure reducer
Joint
Pressure gauge
Fig. 5
Tank
Fig. 6