Functionality of this manual
The mounting of each different version (e.g. wall, ceiling,
with side panel) is described separately. Mount the system as
described in the respective chapter of your manual.
Regarding these instructions
These instructions are for the installation of the MUTO sli-
ding door system Telescopic. These instructions describe the
installation of a left hand door. Use mirror image for a right
hand door.
Target group
Only properly qualified staff is authorized to mount dormakaba
glass fittings.
Symbols used – Safety
Caution!
Fittings must meet the requirements of
substructure/wall and door weight. Please read the
technical information for fittings.
Risk of breaking glass
When fitting the door, support the panel with a block
of wood or similar object.
Risk of crushing!
A
Position buffer stop so door handles (optional) are at
least 25 mm away from the wall.
Always use silicone- and oil-free cleaners
(e.g. acetone).
Symbols used – Installation
Read notes
Reference to deviating installation steps
for different versions
A 2
(Example here: wood panel, step 2)
A
1 2
Installation sequence
Individual steps within an installation step
1
2
Closing edge
LL = slow runner
SL = fast runner
6
Safety instructions
- Installation requires two people
- Always wear protective clothing
Intended use
- for sliding doors in dry indoor areas only
- for manual slow opening and closing only, door leaf
must be stopped manually before reaching end position
Wall/Ceiling requirements and fittings
- The substructure/wall must be able to bear permanent
loads, be level and perpendicular (max. tolerance:
2 mm per meter).
- Fittings must be sufficiently dimensioned for the
substructure/wall and for the weight of the door.
Please read the technical information for fittings.
- Fittings are not included.
Requirements for glass panel:
- Heat-soaked thermally toughened safety glass
(ESG-H in compliance with DIN EN 12150-1)
- Laminated safety glass (LSG in accordance with
EN ISO 12543-1)
- Clamping area must be level and uncoated
(no self-cleaning coating!)
Maintenance, care, repair
- minimum of 5 years maintenance-free operation
(based on 50 cycles per day)
- if operated frequently, check and retighten the
cable if necessary
- immediately replace damaged parts
- always use original dormakaba parts
- use a damp cloth for occasional cleaning especially
of the track
Disposal
Dispose in accordance with national regulations.