5 Carrying out Measurements

B
For measurements on current-
carrying components, the applied
voltage must not exceed 24 V /~,
otherwise the thermometer may be
damaged. In case of voltages
equal to or greater than 42 V, there
is a hazard of an electric shock. If
two temperature sensors are used
simultaneously, the voltage differ-
ence on the components to be
measured must not exceed 1 V.
Only use the supplied temperature
sensors for measurements up to
max. 260 °C (500 °F). Higher tem-
peratures will damage the insula-
tion.
Do not bend the sensor leads, es-
pecially avoid bends near the con-
nectors. Otherwise the sensors will
be damaged.

5.1 Basic adjustments

5.1.1 Selecting the type of tempera-
ture sensor
The two supplied temperature sensors
are K-type. The thermometer is factory-
set to this type. On the display (2), the
letter K precedes both the main display
(a) and the second display (b).
1) To change the sensor type, sensor T1
must be selected for the main display
and sensor T2 for the second display
(standard adjustment after switching
on). The sensor number (T1, T2) is
indicated on the right side of each
temperature display.
If the sensor number must be
changed, press the buttons "T1 T2/
T1-T2" so many times until the cor-
rect sensor has been selected [button
(5) for the main display and button (8)
for the second display].
2) Press the button "TYPE" (11) for sen-
, it is switched
5.1.2 Switching between Celsius and
With the button "°C/°F" (4), switch the
temperature indication from Celsius to
Fahrenheit and vice versa.

5.1.3 Setting the internal clock

After switching on, the time display (c)
shows the time which has passed since
the thermometer was switched on. This
can be used to indicate the measuring
time. The current time can also be dis-
played there, if required. It must be
entered first:
1) Press the button "SET" (12). The
2) Press the button "HOLD" (9) three
3) For all buttons, now the marking
4) After entering the time, start the clock
5.2 Measuring the temperature and
1) Select the sensor number (T1, T2)
2) Hold the sensor or the sensors to the
3) To measure the temperature differ-
sor T1 and the button "TYPE" (14) for
sensor T2 so many times until the
correct sensor has been selected.
Fahrenheit
main display (a) shows
times so that the time display (c)
shows
.
above the buttons applies so that the
current time can be entered via the
corrresponding buttons.
by actuating the button "HOLD".
the temperature difference
with the buttons "T1 T2/T1-T2" [but-
ton (5) for the main display (a) and
button (8) for the second display (b)].
In the standard adjustment after
switching on, T1 is selected for the
main display and T2 for the second
display. This is indicated on the right
side of the temperature display.
object to be measured and read the
temperature/s on the display (2).
ence between the sensors (T1 minus
T2), press the button "T1 T2/T1-T2"
[(5) or (8)] so many times until "T1-
T2" is displayed. For this function, the
sensor type is not displayed (display
"–").