WARNING:
Before performing any maintenance, make sure the
sweeper battery is removed to avoid accidental starting
and possible serious personal injury.
WARNING:
When servicing, use only authorized replacement parts.
Use of any other parts can create a hazard or cause
product damage.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and can be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or
destroy plastic which could result in serious personal
injury.
Remove any build-up of dirt and debris on the top, sides,
and bottom of the tool housing. Wipe the sweeper clean with
a dry cloth occasionally. Do not use water.
NOTE: ILLUSTRATIONS START ON PAGE 11
AFTER FRENCH AND SPANISH LANGUAGE SECTIONS.
MAINTENANCE
STORING THE CORDLESS SWEEPER
See Figures 12 - 14, pages 12 - 13.
Turn the motor OFF and remove the battery pack.
Push the bristle deflectors all the way down.
Push and hold the push-pin button on the handle
assembly.
Retract the handle assembly until the buttons snap into
the holes closest to the handle grips.
Tilt the handle assembly completely forward until it is past
the front detent and resting on the bristle deflectors.
Place the unit in an upright position with the handle facing
up.
REPLACING THE BRUSHES
See Figures 15 - 17, page 13.
Over time, the brushes can become worn and need
replacement. For even cleaning, it is recommended that the
left and right brushes be replaced at the same time.
To replace the brushes:
Turn the motor OFF and remove the battery pack.
Put the unit in the storage position.
Remove the screws securing the bracket and remove the
bracket.
Pull the caster assembly and support away from the
sweeper.
Remove the worn brush from the shaft.
Place a new brush and support on the shaft.
NOTE: The left and right brushes are not interchangeable.
When installed, the bristles at the top of each brush
should point up and away from the center of the tool as
shown in figure 17.
Replace the caster assembly.
Replace the bracket and secure with screws.
9 — English