Troubleshooting
All of the tools in the Oregon 120V Professional Series have the ability to self-diagnose issues
Below is a table of fault codes the tool can display through the dashboard
INDICATORS
LEDs
none
1 continuous red light
1 slow blinking red light
alternating green and red lights
4 green, 1 red, 1 blue quick blinking lights
green green green green red
1 short, 1 long blinking red light
2 short, 1 long blinking red light
4 green and 1 red continuous lights
green green green green red
5 blinking green lights
green green green green green
16
Troubleshooting
SOUND
none
steady on
red
slow beep
(repeating)
red
rapid beep
(repeating)
green red
very rapid
short beep
(repeating)
blue
1 short,
1 long beep
red
2 short,
1 long beep
red
none
none
POSSIBLE
CAUSE
Trigger not pulled.
Pull trigger.
Make certain the plug
No power.
is fully seated in socket.
Disconnect the battery
plug from the tool.
Fan is jammed.
Service tool. Contact
authorized repair center.
Battery is fully
Charge battery.
discharged.
Service battery.
Battery fault.
Contact authorized
repair center.
Unplug, wait 30
seconds, plug back in.
Hardware fault.
Service tool.
Contact authorized
repair center.
Battery too hot.
Allow battery to cool.
Tool over temp.
Allow tool to cool.
Failed dashboard.
Replace dashboard.
Trigger pulled
Release trigger or
or trigger lock
position trigger lock to
engaged in "ON"
"OFF" position.
position while
Unplug tool.
battery plug is
Check for stuck trigger.
inserted.
Plug in tool.
Backpack Blower Model BL120VX-NA
RECOMMENDED
ACTION