PANEL INSTALLATION
Custom Panels
DOOR PANEL HEIGHT
The height of the custom door panel can extend beyond the
typical panel height, provided it does not exceed the weight
limit. Refer to the illustration below.
45
mm
A DECORATIVE VALANCE
CANNOT EXTEND
3 mm
BEYOND THIS PLANE
DOOR
PANEL
2134
610 mm
mm
TO BACK OF UNIT
HINGE
Upper valance (column and tall models)—side view.
TOE KICK CLEARANCE
The height of the toe kick area can extend beyond the
typical toe kick height, provided it does not exceed the
dimensions in the illustration below.
HINGE
VENTED
LOUVERS
610 mm
TO BACK OF UNIT
DOOR
PANEL
29 mm
MAX
TOE KICK
ADJUSTMENT
102 mm
A DECORATIVE TOE KICK
TO
CANNOT EXTEND
152 mm
BEYOND THIS PLANE
FROM FLOOR
Toe kick area—side view.
Panel Installation
DOOR PANEL INSTALLATION
Typical panel dimensions are based on a 2134 mm finished
height with 3 mm reveals. Template placement must be
adjusted for panels exceeding typical dimensions.
For tall models, the door panel should be installed first,
followed by the upper then lower drawer panel.
Place the panel face down on a protected work surface.
Position the template flush with the top and sides of the
panel. Verify the correct side of the template is being used,
then mark and drill holes. Refer to the illustration below.
For tall models, align the notch in the template with the
bottom of the door panel, then mark and drill holes. Refer to
the illustration below.
TOP OF DOOR PANEL
TOP OF
DOOR PANEL
84" APPLICATION
83 7/8" ACTUAL
BOTTOM OF
DOOR PANEL
BOTTOM OF
USE TABS FOR HINGE
DOOR PANEL
SIDE PANEL EDGE ON
DUAL INSTALLATION
Door panel template—top.
Door panel template—bottom
(tall models only).
Use the T-20 torx drive provided, to partially insert a #8 x 13
mm screw into the second hole from the top on each side of
the panel. The screws should be approximately 4 mm proud
of the panel and will support the weight of the panel during
installation.
Align the support screws on the back of the panel with the
slotted holes on both door mounting brackets. Opening
the door slightly may help with alignment. Once the panel
is supported by the screws, partially insert a #8 x 13 mm
screw into the second hole from the bottom on each side of
the panel, but do not tighten.
CAUTION
As the reveal between cabinets and the unit decreases,
the potential exists for severe finger pinching if fingers
are placed in the opening when the door is closing.
BACK OF
DOOR PANEL
Door panel mounting.
subzero.com
|