12. MAINTENANCE TABLE
Intervention
MACHINE
Check all fasteners
Safety checks/check controls
Check the battery charge status
Recharge the battery
Cleaning the machine
Checking for any damage to the machine. If
necessary, contact the authorised service centre.
* Refer to the battery/battery charger manual.
13. PROBLEM IDENTIFICATION
PROBLEM
1. The machine does
not start when the
switch is moved
2. The motor shuts
down whilst working
3. The rotor rotates, but
the air does not come
out from the blower tube
4. Excessive noise and/or
vibration is experienced
whilst working
5. The machine gives off
smoke whilst working
6. Battery power
reserve is low
PROBABLE CAUSE
Battery is not inserted or
is inserted incorrectly
Low battery
Defective start/stop switch
or
damaged blower
Battery is not inserted correctly
Low battery
Blocked or clogged blower tube
Loose or damaged parts
Damaged blower.
Severe working conditions
requiring greater
current absorption
Battery is insufficient for
operating requirements
Decrease in battery capacity
Frequency
Before each use
Before each use
Before each use
After each use
After each use
After each use
Make sure that the battery is
inserted correctly (par. 7.2.3)
Check the battery status and
recharge if necessary (par. 7.2.2)
Do not use the machine. Immediately
turn off the machine,
and
contact a service centre.
Make sure that the battery is
inserted correctly (par. 7.2.3)
Check the battery status and recharge if
necessary
. (par. 7.2.2)
Stop the machine,
and remove any obstructions.
Turn off the machine,
–
inspect for damage;
–
check for and tighten any loose parts;
–
have any damaged parts replaced
or repaired with parts having
equivalent specifications.
Do not use the machine. Immediately
turn off the machine,
and
contact a service centre.
Optimise operations
(par. 7.2.1)
Use a second battery or extended
battery (par. 14.1)
Purchase a new battery
EN - 13
Notes
par. 7.4
par. 6.2
*
par. 7.2.2
*
par. 7.3
-
SOLUTION
remove the battery
remove the battery
remove the battery and:
remove the battery