Amp
Set w elding
current
Arc power can be adjusted between 0 and 100% of
the welding current setting.
E.g.
If the welding current is set to 40A and arc power to
50% the additional current is 20 A equals 60 A when
doing arc power. If the arc power is set to 100% the
additional current is 40 A equals 80 A when doing arc
power.
Torch adjustment /
remote control – 7-poled plug
The regulation of welding current is made by
means of the torch potentiometer (optional). The
maximum current reachable is the level previously
adjusted on the front panel. The minimum current is
5A.
External adjustment –
8-poled plug (optional)
Can be used for foot pedal (optional) and
remote control units (optional) that use a 8-poled plug.
The function is used for arc ignition and adjustment of
the current. The maximum current reachable is the
level previously adjusted on the front panel. The actual
current is shown on the display.
Start amp can be used as a setting of minimum
current as a percentage of maximum current.
Please note: The machine will automatically start in two-times in
this function when the machine uses a software version before
1.12
Ignition methods
It is possible to choose between 2 different
methods of ignition for TIG welding: High-
Frequency (HF) and LIFTIG ignition. The ignition
method cannot be changed during welding. The
LIFTIG ignition is active when the indicator is
illuminated. The HF is automatically active when the
LED is switched off.
HF-ignition
In HF-TIG ignition the TIG arc is ignited without
contact. A high-frequency (HF) impulse initiates the
arc when the torch trigger is activated.
The HF will not arise and the machine will stop if the
electrode is in contact with the workpiece. Detach the
electrode and start again.
LIFTIG-ignition
In LIFTIG ignition the TIG arc is ignited after making
contact between the workpiece and the tungsten
electrode, after which the trigger is activated and the
arc is established by lifting the electrode from the
workpiece.
Additional curre nt
supply from the arc
pow er function
short-
time
circuit

Trigger mode

Selection of trigger mode. Four-times trigger
mode is active when the LED is illuminated,
and two-times trigger mode is active when the LED is
turned off. It is not possible to change trigger method
during the welding process.
Two-times
The welding process begins by pressing the torch
trigger. Welding continues until the trigger is released
again which effects the slope-down period.
Four-times
The welding process begins by pressing the torch
trigger. If the torch trigger is released during the slope-
up period welding continues with the adjusted welding
current. In order to stop the welding process the
trigger must be pressed again for more than 0.5s after
which the slope-down period begins. The slope-down
period can be stopped by releasing the trigger.
Thereafter the post-flow starts.
It is possible to configure the machine to work in 3
different ways when this mode is selected. For
detailed information read the section "USER MENU" of
this manual about "4t.o."
Anti-freeze
This machine is provided with an anti-freeze control.
The anti-freeze-control reduces the current when the
electrodes stick to the weld piece. This makes it easier
to break off the electrode and welding can continue.
Reset
It is possible to recall all factory standard parameters.
In this case all programs in the machine will be reset
to the following value:
MMA current 80A
TIG Current 80A
TIG Spot Current 80A
Pre-flow 0.0 sec
Post-flow 6.0 sec
No slope-up/slope-down
Start amp 40%
Stop amp 20%
Second Current level 50%
Base amp 40%
Fast pulse frequency 49Hz
Pause time = Pulse time = 0.1 sec
AC-T-Balance (AC) 65%
Electrode Pre-heating (AC) 5
Frequency (AC) 50%
AC-I-Balance (AC) 100%
The Reset procedure is as follows:
Switch off the machine and wait until display is
extinguished.
Press the following key pads
simultaneously:
Switch on the machine and keep the above keys
pressed until the display shows "X.XX". Then release
the keys.
X.XX is the software version of program.