Connecting A Gas Dryer - GE DPGT750 Manual Del Propietario E Instrucciones De Instalación

Ocultar thumbs Ver también para DPGT750:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation instructions
CONNECTING
A GAS DRYER (cont.)
GAS REQUIREMENTS
-& WARNING
,, Installation
must
conform
to local
codes
and ordinances,
or in their
absence,
the
NATIONAL
FUEL GAS CODE, ANSI
Z223.
,, This gas dryer
is equipped
with
a Valve
and
Burner
Assembly
for use only
with
natural
gas. Using
conversion
kit WE25X10014,
your
local
service
organization
can convert
this dryer
for use with
propane
(LP) gas.
ALL CONVERSIONS
MUST
BE MADE
BY PROPERLY
TRAINED
AND
QUALIFIED
PERSONNEL
AND
IN ACCORDANCE
WITH
LOCAL
CODES AND ORDINANCE
REQUIREMENTS.
,, The dryer
must
be disconnected
from
the gas supply
piping
system
during
any
pressure
testing
of that system
at a test
pressure
in excess
of 0.5 PSI (3.4 KPa).
,, The dryer
must
be isolated
from
the
gas supply
piping
system
by closing
the
equipment
shut-off
valve
during
any
pressure
testing
of the gas supply
piping
of test pressure
equal
to or less than
0.5 PSI (3.4KPa).
DRYER GAS SUPPLY CONNECTION
I
31/4"
_
.,r_,
j
I
(8.2 cm)
1
',
3/8" NPT MALE THREAD GAS SUPPLY
(6
cm)
NOTE:
Add
to vertical
dimension
the distance
between
cabinet
bottom
to floor.
GAS SUPPLY
,, A 1/8" National
Pipe Taper thread
plugged
tapping,
accessible
for test gauge
connection,
must
be installed
immediately
upstream
of the gas supply
connection
to
the dryer.
Contact
your
local
gas utility
should
you
have questions
on the
installation
of the plugged
tapping.
,, Supply
line is to be 1/2" rigid
pipe and
equipped
with
an accessible
shut-off
within
6 feet of, and in the same
room
with,
the
dryer.
,, Use pipe compound
appropriate
for natural
or LP gas or use Teflon ® tape.
,, Connect
flexible
metal
connector
to dryer
and gas supply.
IN THE COMMONWEALTH
OF MASSACHUSETTS
,, This product
must
be installed
by a licensed
plumber
or gas fitter.
,, When
using
ball-type
gas shut-off
valves,
they
shall
be the T-handle
type.
,, A flexible
gas connector,
when
used, must
not exceed
3 feet.
ADJUSTING FOR ELEVATION
• Gas clothes
dryers
input
ratings
are based
on sea level
operation
and need not be
adjusted
for operation
at or below
2000 ft.
elevation.
For operation
at elevations
above
2000 ft., input
ratings
should
be reduced
at
a rate of 4 percent
for each 1000 ft. above
sea level.
• Installation
must
conform
to local codes
and ordinances
or, in their
absence,
the
NATIONAL
FUEL GAS CODE, ANSI
Z223.
22

Publicidad

Capítulos

Tabla de contenido
loading