6) After setting the first scene, press the button
MENU. The display indicates the number of
the scene again. Use the button UP to select
the second scene, press ENTER and then
select the settings for this scene. Repeat this
procedure for the following scenes. If not all
30 scenes are required, enter 0 as the value
for the numbers of scenes that are not to be
used.
4.2 Synchronous control of multiple
spotlights (master / slave mode)
Multiple ODC-100 / RGB and PARC-100 / RGB
(also a combination of both) may be connected.
The master unit can then control all slave units
in sync.
1) Connect the spotlights via their DMX jacks to
a chain. Please refer to chapter 4.3.1 "Con-
nection", ignoring step 1.
2) The units that are to be controlled by the
master unit must be defined as slave units:
a) Press the button MENU repeatedly until
the highest menu level has been reached.
b) Press the button UP or DOWN repeatedly
until the display indicates
c) Press the button ENTER and then use the
button UP or DOWN to select:
=master unit
= slave unit
3) Any sequences of scenes that have been
stored on the master unit (chapter 4.1.5) may
be copied to the slave units:
a) On the master unit, press the button
MENU repeatedly until the highest menu
level has been reached.
b) Press the button UP or DOWN repeatedly
until the display indicates
c) Press the button ENTER. The display
indicates
or
.
d) Press the button UP or DOWN repeatedly
until the display indicates
e) Press the button ENTER so that the dis-
play indicates four entry positions (. . . .).
Then press the following buttons:
UP, DOWN, UP, DOWN.
Each time one of these buttons is
pressed, an asterisk ( ) will appear on the
display.
18
.
.
,
,
,
,
.
f) Press ENTER to start copying. During
copying, the spotlight lights up in yellow. If
an error occurs, the spotlight will light up
in red. Upon successful completion, the
spotlight will light up in green.
g) To switch on the operation mode desired,
press the button MENU so that the display
indicates
and DOWN to select the operating mode
and then press ENTER to activate it.

4.3 Operation with a DMX controller

DMX is short for Digital Multiplex and means
digital control of multiple DMX units via a com-
mon control line. For operation via a DMX con-
troller (e. g. DMX-1440 or DMX-510USB from
"img Stage Line"), the spotlight is equipped with
10 DMX control channels. However, it can, if
required, also be controlled via 5, 4 or 3 chan-
nels only. Please refer to chapter 4.3.5 for more
information on channel functions and DMX val-
ues.

4.3.1 Connection

For DMX signal transmission, special cables
should be used (e. g. CDMXN-... from "img
Stage Line"). For cable lengths exceeding
150 m or for control of more than 32 units via a
single DMX output, it is generally recommended
to insert a DMX level matching amplifier (e. g.
SR-103DMX).
1) Connect the input DMX IN to the DMX output
of the light controller or to the DMX output of
another DMX-controlled unit.
For the spotlight ODC-100 / RGB, connect
the plug (C) of the cable DMX IN to the inline
jack (D) of the supplied cable equipped with
an XLR plug. Then fasten the nut to secure
this connection.
DMX IN
C
DMX connection ODC-100 /RGB
Use an extension cable to connect the XLR
plug to the DMX output of the light controller
or, if additional DMX-controlled units are
used, to the DMX output of the last DMX-con-
trolled unit.
2) Connect the output DMX OUT to the DMX
input of the second DMX unit. Connect the
output of the second DMX unit to the input of
again. Use the buttons UP