7.3
COFFEE DELIVERY
On pressing the corresponding key T1-T2-T3
or T4, the corresponding delivery solenoid
valves are activated for the time necessary
to obtain the required amount of product as
previously programmed (volumetric check).
The LED relative to the selected measure re-
mains on for the entire coffee delivery time.
The delivery in progress may be suspended
before actually reaching the desired program-
med product quantity by pressing any of the
measure keys present on the keyboard of the
unit used for product delivery.
It is also possible to obtain simultaneous coffee
delivery from all the machine units.
7.4
CONTINUOUS COFFEE
MEASURES
For continuous coffee measure delivery press
key T5 from the keyboard corresponding to the
unit on which one wishes to operate.
The LED corresponding to key T5 will remain
on for the entire delivery operation.
IMPORTANT ! Avoid keeping it pressed
for more than 5 seconds or it will enter the
programming mode.
Coffee delivery will continue until measure
stop by pressing key T5, or on obtaining the
maximum amount of product which can be
obtained through volumetric control (6000
impulses) or by means of delivery Time-out
function.
IMPORTANT ! The start of the relative "con-
tinuous" cycle occurs on the release (within
5 seconds) of key T5 and not on pressing of
the same. While the STOP function may be
obtained by pressing it a second time.
T1
T5
35
ENGLISH