Preparing the vacuum cleaner
6.1
The appliance is supplied and equipped with a microfibre filter (P) which is
already assembled.
WARNING: For safety reasons, the handgrip (T) can be released only if
the quick connector (24) is not inserted.
•
Lift the safety cover (V)
•
Lift the quick connector (24) of the flex by pressing the front button (25)
into the steam socket (W)
•
Make sure it is properly fastened: button (25) should return to its initial
position; once in position it should click.
•
Plug the power cable (B) into an appropriate socket provided with an
earthing system.
•
Press the main switch (D); the pilot light (H) will come on.
Starting up the boiler
6.2
CAUTION!
When preparing the appliance for use, switch it off and unplug it.
WARNING:
The appliance must be placed on a horizontal flat surface.
•
Remove the boiler water tank cap (C)
•
Fill the boiler tank (max1.2 litres) using the recharging automatic valve bot-
tle (19a)
(picture 5)
is completely filled.
•
Put on the boiler water tank cap (C)
Replacing the filter
6.3
•
Press the two buttons (U) located besides the handgrip (T) down
completely
(picture 7)
•
Lift up the handgrip (T)
•
Lift up the handle (N) and remove the tank (M)
•
Turn the tank handle (N) over and pull the filter
assembly with float (O) up/forward
•
Replace the filter (P) or (Q) in its container
•
Fit the lower filter cover (S) completely