Time programming
Programming the time is done in the same way both for heating and for DHW; the two programs are independent.
To program Heating access the "Time Program" menu following the path "USER MENU
gram".
To program Domestic hot water (DHW) access the "Time Program" menu following the path "USER MENU
MESTIC HOT WATER"
Choose the desired type of programming and follow the instructions given below.
Select the day (fig. 16) or the interval of days to be programmed (fig. 17) and confirm with the OK button.
Scheduler Set
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Monday-Sunday
to confirm
The program is weekly, which means that 6 independent time bands can be set for each day of the week (fig. 18); 4
options can be selected for each time band:
ON. In case of a Heating/DHW demand, the boiler works at the set Heating/DHW (fig. 12/fig. 14) Adjustment Tem-
perature.
In case of a Heating/DHW demand, the boiler works at the Reduced Adjustment Temperature. The Reduced tem-
perature is obtained by subtracting the Reduction Adjustment Temperature value (fig. 13/fig. 15) from the set Hea-
ting/DHW Adjustment Temperature (fig. 12/fig. 14).
OFF. In case of a Heating/DHW demand, the boiler will not activate the Heating/DHW mode.
-- : -- OFF. Time band disabled.
The boiler is sold with time program not activated. In fact, every day it will be programmed from 00:00h to
A
24:00h in ON mode (fig. 18).
First, set the start time of the first time band (fig. 18) using the contextual buttons 1 and 2.
Press the navigation button 7 to move to the end time of the first time band (fig. 19) and set it to the desired value using
the contextual buttons 1 and 2.
128
"Time Program".
5
7
fig. 16
Scheduler Set
1.
00:00
- 24:00
2.
--:-- - --:--
3.
--:-- - --:--
4.
--:-- - --:--
--:-- - --:--
5.
6.
--:-- - --:--
Copy to the Next Day
Save & Exit
to confirm
cod. 3541T170 - Rev. 00 - 09/2019
Scheduler Set
Wednesday
Thursday
Friday
Saturday
Sunday
Monday-Sunday
Monday-Friday
Saturday-Sunday
to confirm
1
2
fig. 18
FORCE B
"HEATING"
"Time Pro-
5
7
fig. 17
"DO-
EN