Adjustments from remote timer control
If the Remote Timer Control (optional) is connected to the boiler, the above adjustments are managed accor-
A
ding to that given in table 1.
Table 1
Heating temperature adjustment
DHW temperature adjustment (with
optional hot water tank installed)
Summer/Winter Switchover
Eco/Comfort selection (with optional hot
water tank installed)
Sliding Temperature
System water pressure adjustment
The filling pressure with the system cold must be approx. 1.0 bar. If the system pressure falls to values below minimum,
the boiler card will activate fault 37 and the number of the module (fig. 30).
Once the system pressure is restored, the boiler will activate the 300-second air venting cycle indicated on the
A
display by FH.
EN
The adjustment can be made from the Remote Timer Control menu and the boiler control panel.
The adjustment can be made from the Remote Timer Control menu and the boiler control panel.
Summer mode has priority over a possible Remote Timer Control heating demand.
On disabling DHW from the Remote Timer Control menu, the boiler will select the Economy
mode. In this condition, the button detail 10 - fig. 1 on the boiler panel is disabled.
On enabling DHW from the Remote Timer Control menu, the boiler will select the Comfort
mode. In this condition, with the button detail 10 - fig. 1 on the boiler panel it is possible to select
one of two modes.
Both the Remote Timer Control and the boiler card manage Sliding Temperature adjustment:
Sliding Temperature overrides the boiler card.
Nr:37
Src:1
fig. 30 - Module 1 insufficient system pressure fault
cod. 3541T170 - Rev. 00 - 09/2019
133