A - Upstream pressure point
B - Downstream pressure point
R
I - Gas valve electrical connection
R - Gas outlet
S - Gas inlet
B
I
A
TYPE SGV100
Pi max 65 mbar
24 Vdc - class B+A
S
fig. 18 - Gas valve
Heating power adjustment
To adjust the heating power, switch the boiler to TEST mode (see sec. 4.1). Press the
heating buttons detail 3 - fig. 1 to increase or decrease the power (min. = 00 - max. =
100). Press the reset button within 5 seconds and the max. power will remain that just
set. Exit TEST mode (see sec. 4.1).
Configuration Menu
Press the DHW buttons together for 10 seconds to access the configuration Menu. 8 pa-
rameters are available, indicated by the letter "b", which are not modifiable from Remote
Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to view or modify the value of a parameter: the modification
will be automatically saved.
Contents
Description
Range
0=Natural Gas
b01
Gas type selection
1=LPG
1=Bithermal instanta-
neous
2=Monothermal
instantaneous
b02
Boiler type selection
3=Heating only (3-way
valve)
4=Heating only (circu-
lating pump)
0=Sealed Chamber
combustion control
(without fume pres-
sure switch)
1=Open Chamber
(with fume thermostat)
2=Sealed Chamber
(with fume pressure
switch)
3=Sealed Chamber
Combustion chamber
b03
combustion control
type selection
(with fume thermostat
on recuperator)
4=LOW NOx Sealed
Chamber Combustion
control
(without fume pres-
sure switch)
5=LOW NOx Open
Chamber
(with fume thermostat)
0=Flat
Primary Exchanger
type selection
1=Omega
(b03=0)
2=--
No effect on adjust-
ment (b03=1)
No effect on adjust-
ment (b03=2)
b04
0=Flat
Primary Exchanger
type selection
1=Omega
(b03=3)
2=--
No effect on adjust-
--
ment (b03=4)
No effect on adjust-
--
ment (b03=5)
1 2 3 4
~ 24W
fig. 19 - Gas valve connection
Default
0=Natural Gas
0=Natural Gas
1=Bithermal instanta-
2=Monothermal
neous
instantaneous
0=Sealed Chamber
0=Sealed Chamber
with
with
combustion control
combustion control
(without fume pres-
sure switch)
0=Flat
0=Flat
--
0
--
0
0=Flat
0
0
cod. 3541F120 - Rev. 00 - 03/2014
Contents
Description
Auxiliary relay card
(b02=1)
operation selection
(b02=1)
No effect on adjust-
b05
ment (b02=2)
No effect on adjust-
ment (b02=3)
No effect on adjust-
ment (b02=4)
Mains Voltage Fre-
~ 65W
b06
quency
Comfort burner on
time
(b02=1)
No effect on adjust-
ment (b02=2)
b07
No effect on adjust-
ment (b02=3)
No effect on adjust-
ment (b02=4)
b08
Driver Gas valve
Notes:
1.
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the pa-
rameter given in brackets is modified.
To exit the configuration Menu press the DHW buttons together for 10 seconds, or exiting
occurs automatically after 2 minutes.
FL 24 MCS
Range
Default
0=External gas valve
1=System filling sole-
0=External gas valve 0=External gas valve
noid valve
2=Solar 3-way valve
--
0
--
0
--
0
0=50Hz
0=50Hz
0=50Hz
1=60Hz
0-20 seconds
5 seconds
5 seconds
--
5
--
5
--
5
0 = Standard, 1
0=Standard
0=Standard
EN
FL 24 MCS
7