Environment And Recycling - Grohe Blue Chilled & Sparkling 40 554 Manual Del Usario

Ocultar thumbs Ver también para Blue Chilled & Sparkling 40 554:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Cleaning cooler/carbonator
For hygienic and healthy reasons, the cooler/carbonator
must be cleaned once a year. Cleaning must be
performed before changing the filter cartridge, in order to
prevent contamination of the replacement filter cartridge.
Note: The cleaning kit (Prod. no.: 40 434 001) and the
accompanying adapter (Prod. no.: 40 694 000 or 40 699 000)
could be ordered at www.grohe.com.
Service
Note the Fault/ Cause/ Remedy table for information on
eliminating problems.
If EE flashes or the problem cannot be rectified, interrupt the
power supply to the cooler/carbonator. Note down the serial
number of the cooler/carbonator on the rear of the device and
consult a specialist installer or contact the GROHE Service
Hotline via email under TechnicalSupport-HQ@grohe.com.
The GROHE Blue
®
Chilled cooler/carbonator may only be
repaired by GROHE Service.
Fault
Cause
Water not flowing
• Water supply interrupted
No filtered water,
• Safety shut-off of pump
®
Blue
handle flashes
red, E1 in the display
No filtered water, E2
• Exceeding the drawing time
in the display
No filtered water, E3
• No connection between fitting and
in the display
cooler/carbonator
• Cable or connector faulty
No filtered water,
• Fitting and cooler/carbonator not
synchronized
®
Blue
handle flashes
red, E4 in the display
No filtered water,
• Fault function of cooler/carbonator
®
Blue
handle flashes
red, E5 in the display
No filtered water,
• Values range does not concur
®
Blue
handle flashes
red, E6 in the display
No filtered water, E7
• Fault function of cooler/carbonator
in the display
• Filter capacity exceeded
®
Blue
handle flashes
orange, E8 in the
display
E9 flashes alternately
• cooler/carbonator overheated
with HI in the display
No carbon dioxide in
• CO
positions Medium
and Sparkling
cylinder not opened or empty
2

Environment and recycling

Used filter cartridges can be disposed of hazard-free in
domestic waste.
The accompanying CO
cylinder can be refilled locally.
2
The CO
cylinder must not be sent back. At the end of its
2
useful life it must be disposed of locally in accordance with the
applicable regulations.
Note: A 2 kg CO
cylinder (Prod. no: 40 423 000) can be
2
ordered at www.grohe.com.
The cooler/carbonator is an electrical device, to which return
and take-back obligations apply in many countries. GROHE
participates in such take-back systems in all relevant
countries.
This category of device does not belong in
the domestic waste, but must be disposed of
separately in accordance with the relevant
local national regulations.
Remedy
- Open shut-off valves
- Open shut-off valves
- Disconnect mains supply, wait 30 seconds and
reconnect
®
- Close Blue
handle
- Connect plug-in connector
- Contact GROHE Service
- Synchronise with one another, see section
Installation
- Connect mains supply, wait 30 seconds and
reconnect
- Synchronise with one another, see section
Installation
- Connect mains supply, wait 30 seconds and
reconnect
- Change filter cartridge immediately
®
- Close Blue
handle, ensure ventilation and reduce
ambient temperature to max. 50 °F
- Disconnect mains supply, wait 30 seconds and
reconnect
- Fully open valve of CO
cylinder
cylinder or replace
2
6

Publicidad

Tabla de contenido
loading

Tabla de contenido