Application; Technical Specifications; Id 08200; Scope Of Delivery - Franke PROTRONIC - A3000 Instrucciones De Montaje

Ocultar thumbs Ver también para PROTRONIC - A3000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.

Application

PROTRONIC - A3000 open, non-contact, opto-electronically controlled urinal flush
valve for wall installation, with the option of external control, such as valve settings
and communication via ECC function controller. The flush time can be set in one
second steps.
6.

Technical specifications

Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculated flow rate:
Flushing flow:
Flush water volumes:
Operating voltage:
Power consumption:
Communication:
Protection class:
7.

ID 08200

8.

Scope of delivery

Pos.
Name
1
Cover plate with sensor
2
Self-closing solenoid valve cartridge
3
Electronic module M2
4
Supporting frame (attached to the cover plate)
5
Accessories kit:
Installation material and seals
Installation and operating instructions
9.

DimensionsInstallation example

1.0 - 4.0 bar
1 - 5 bar
10 bar
0.30 l/s
0.30 - 0.70 l/s
2 - 4 l/s adjustable
24 V DC
3.5 W
Ethernet via ECC function controller
IP 68
- 5 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aqua401

Tabla de contenido