Velleman PIR416 Manual Del Usuario página 4

Mini detector de movimientos pir – para empotrar
Ocultar thumbs Ver también para PIR416:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
• Damage caused by disregard of certain guidelines in this manual
is not covered by the warranty and the dealer will not accept
responsibility for any ensuing defects or problems.
4.
Installation
Refer to the illustrations on page 2 of this manual.
The installation must be carried out by a qualified person.
1. Choose a proper location for the sensor. Avoid places where
temperature changes frequently, e.g. near air conditioners or
heating devices. Also avoid moving obstructions or objects in the
detection field of the sensor to prevent unnecessary activation.
2. The PIR sensor must be installed inside a hole which is max.
12 mm in diameter. The controller can be installed on the other
side of the wall, inside a dropped ceiling or, behind a false wall.
Leave sufficient space (at least 2 cm) around the controller for
ventilation.
Notes:
• The lead wires of the sensor are ± 20 cm long. When mounting
the controller on the other side of a wall, drill a hole of at least
12 mm for the connector and wires to go through.
• Make sure the controller is accessible at all times when installing
inside a dropped ceiling or behind a false wall. However, it should
be sufficiently protected to avoid accidental touching!
3. A 12 Vdc/2.6 A power supply (not incl.) must be provided.
4. Connect the sensor to the controller [2]. The connector fits only
one way, do not force.
5. Set the DIP switches [3]:
light sensitivity
movement sensitivity
5"
On-time
30"
On time
1'
On-time
3'
On-time
5'
On-time
8'
On-time
Note: only the highest selected on-time will be applicable.
V. 04 – 17/10/2014
PIR416
ON
< 10 lx
low
5 seconds
30 seconds
1 minute
3 minutes
5 minutes
8 minutes
4
OFF
always
high
-
-
-
-
-
-
©Velleman nv

Publicidad

Tabla de contenido
loading

Tabla de contenido