Hints On The Manual; Handling; Transport; Storage - Pfannenberg DTT 601 Serie Instrucciones De La Instalación Y Del Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
Contents
1
Hints on the manual ..................................................... 10
2
Handling ......................................................................... 10
2.1
Transport ......................................................................... 10
2.2
Storage ............................................................................ 10
2.3
Unpacking ....................................................................... 10
3
Scope of delivery and options .................................... 11
3.1
Scope of delivery ............................................................ 11
3.2
Accessories ..................................................................... 11
4
General Information ...................................................... 11
5
ID Plate and Technical Data ......................................... 11
6
Safety .............................................................................. 11
7
Function ......................................................................... 11
7.1
Principles of function ....................................................... 11
7.2
Condensate ..................................................................... 11
8
Installation ..................................................................... 12
8.1
General ........................................................................... 12
8.2
Power connection ........................................................... 12
9
Operationg Conditions ................................................. 13
10
Putting into operation and function ........................... 13
10.1
General remarks ............................................................. 13
10.2
Indicator elements .......................................................... 13
10.3
Test mode / Start-up ........................................................ 13
10.4
Unit characteristics ......................................................... 13
10.5
Door contact .................................................................... 14
10.6
Centralised fault indication ............................................. 14
10.7
units with Multi-Controller) .............................................. 14
10.8
Setting prossibilities ........................................................ 14
11
Cleaning and Maintenance .......................................... 14
11.1
Cleaning .......................................................................... 14
11.2
Maintenace ...................................................................... 14
12
Stopping ......................................................................... 14
13
What to do if ... .............................................................. 15
13.1
General errors ................................................................. 15
13.2
Fault diagnosis ................................................................ 15
13.3
Pfannenberg units with Multi-Controller .......................... 15
13.4
13.5
Fault not rectified? .......................................................... 16
14
Warranty Conditions ..................................................... 16
Read this manual completely and carefully
before installing the unit.
This manual is an integral part of the scope of
delivery and must be kept until the unit is
disposed of.
10
1

Hints on the manual

This handbook contains instructions for the installation and
operation of roof attachment cooling units, series DTT 6x41.
Hint
The technical specifications for each machine along with additio-
nal information on assembly, connections and operation are
contained in the accompanying supplement sheet or on our
homepage (www.pfannenberg.com).
In this manual, safety recommendations and other information are
structured as follows:
Hazard!
If the measures described in the following are not strictly
observed there is danger to life and health.
Hazard!
If the measures described in the following are not strictly
observed there is danger to life and health due to electri
cal shock.
CAUTION:
If the measures described in the following are not strictly
observed material damage may be caused.
Hint
A hint contains additional information on the action or instruction
described.
2

Handling

2.1

Transport

Do not subject the cooling unit to temperatures below -40°C or
above +70°C during transportation.
Do not subject the cooling unit to relative humidity of over 90%
during transportation.
Lift cooling unit only by the casing or with four jack rings (M8)
Transport the cooling unit only in condition of usage.
Failure to observe these instructions will render the warranty
provisions null and void.
2.2

Storage

Do not subject the cooling unit to temperatures below -40°C or
above +70°C during storage.
Do not subject the cooling unit to relative humidity of over 90%
during storage.
Store cooling unit only in condition of usage.
The storage period is 24 months. The maximum storage period
does not invalidate the respective warranty.
Failure to observe these instructions will render the warranty
provisions null and void.
2.3

Unpacking

Prior to and during unpacking make a visual inspection of the
cooling unit to see whether any damage has occurred during
transport. Especially pay attention to loose parts, dents, scrat-
ches, visible loss of oil etc.
Any damage must be reported immediately to the forwarding
agent (follow the instructions in "Rules for Damage Claims").
Moreover, the latest edition of the "General Conditions for
Supplies and Services" issued by the ZVEI ( Central Association
for the German Electrotechnical Industry") shall apply.
Before disposing of packing material ensure that it does not
contain any loose components.
Danger!
Burr caused by production may be present on the metal
edges of the unit. Always wear protective gloves when car-
rying out maintenance work and installation.
In case of a warranty claim exact details on the fault (photo-
graph, if possible) and the indication of type and serial num-
ber of the cooling unit are required.
085 408 097a

Publicidad

Tabla de contenido
loading

Tabla de contenido