6. Product information
6.4 Technical specifications
M=Medium
S=Standard
P= Internal controller
1= Version 1 (1000 N; 18 mm/s)
2= Version 2 (2000 N; 12 mm/s)
3= Version 3 (3000 N; 8 mm/s)
Tractor-design
Installation dimensions
Standard lifting length
Weight AC Medium
Weight AC Large
Supply voltage
Protection class
Lifting speed
Lifting force
Max. power consumption (primary)
Duty cycle
Max. power consumption
Operating temperature (min./ max.)
Torque load (static)
Version, medium
Torque load (static)
Version, position
52
ACXX n.n/n.n.R n n n
L=Large
AC _ _ 1 _ _ _ ___
M= 200 Nm
M= 450 Nm
F
= 1000 N / 2000 N / 3000 N
Pressurek
F
= 1000 N / 2000 N / 3000 N
Tension
AC _ _ 2 _ _ _ ___
Lifting range + 120 mm
200 - 600 mm
6.5 - 15.0 kg
10.0 - 23.5 kg
selectively 36(24) VDC or 230(115) VAC
18 mm/s
1000 N
4.5 A at U= 24VDC
3.5 A at U= 36VDC
0.7 A at U= 230VAC
S3 / 20 % for 10 minutes
(2 minutes operating time with 8 minutes operating t
According to details on the name plate
-20 °C / +60 °C
approx. Mmax.= 200 Nm
approx. Mmax.= 450 Nm
Consecutive number
Accessories:
0= without
1= Pulse generator (Hall-IC)
2= Potentiometer
Installation height (mm)
Lift (mm
AC _ _ 3 _ _ _ ___
IP 30
12 mm/s
2000 N
8 mm/s
3000 N