7. Life phases

7.3.3 Parallel alignment

If the lifting columns are not parallel to each other, then the
distance between the top fastening points changes during
motion. However, a rigid connection keeps this distance
constant. The consequence is that considerable forces act on
the lifting column guide, which can be damaged by this.
In this case, the lifting columns should also be aligned
exactly. Uneven floors can be compensated by using an
adjustable baseplate.

7.3.4 Bends in the table frames

Table frames are generally made of welded steel tubes and
connection plates for connecting to the lifting columns.
If the connecting plates are not flat against the lifting
column, then the synchro system is stressed during
screwing. This generates unwanted shear forces which
stress the lifting column guide. Please ensure that the
components are working perfectly.
Use the RK SyncFlex compensation plate to compensate
the height difference of two or more lifting columns.
Information on use and technical data of this item can be obtained from the latest
product catalogue.