Fault
Your box does not func-
tion and the fan impeller
which is visible from
outside does not rotate.
The ignition is switched
on and the box does not
work.
Disconnect the plug
immediately from the
socket and execute the
following checks.
Your box does not cool
satisfactorily and the fan
impeller at the outside
does not rotate.
Your box does not cool
satisfactorily and the fan
impeller at the outside
does not rotate.
24
Possible cause
Suggestion
The cigarette lighter in
In the most vehicles, the ignition switch
your vehicle does not
must be switched on, so that the cigarette
conduct any voltage.
lighter has voltage.
The socket of the ciga-
Clean the socket of the cigarette lighter
rette lighter is dirty.
with a non-metallic brush and a solvent, so
This results in a poor
that the middle contact pin is clean. If your
electrical contact.
cooling box plug becomes very warm in
the cigarette lighter box, either the socket
must be cleaned or the plug is possibly not
correctly assembled.
The fuse of the con-
Replace the fuse of the connecting cable
necting cable is burnt
(5 A).
through.
The vehicle fuse is
Replace the vehicle fuse of the cigarette
burnt through.
lighter (usually 15 A). (Observe the operat-
ing instructions in your motorcar for this).
The ventilator motor is
The repair can be executed only by an
defective.
authorized customer service.
The ventilator motor
The repair can be executed only by an
for the inner ventilator
authorized customer service.
is defective.
The thermo-electric
element is defective.
The integrated power
The repair can be executed only by an
unit is defective.
authorized customer service.