Troubleshooting

Fault
The device does not
work.
The device is not
cold enough.
EN
Possible cause
The device is not connected to a
power supply.
The device is switched off.
The circuit breaker tripped.
The fuse has blown.
The temperature is not set prop-
erly.
The ambient temperature could
require a higher temperature set-
ting.
The door was opened frequently. ➤ Do not open the door more
The door was not closed prop-
erly.
The door is not hermetically
sealed.
The condenser is too dirty.
The ventilation opening is
blocked.
Troubleshooting
Remedy
➤ Connect the device, see
chapter "Connecting the
device to the power supply"
on page 29.
➤ Switch the device on, see
chapter "Switching the
device on/off" on page 32.
➤ Switch on the circuit breaker.
➤ Replace the fuse.
➤ Check the set temperature.
➤ Set a higher temperature (see
chapter "Setting the tempera-
ture" on page 32).
often than necessary.
➤ Close door properly.
➤ Check the door seal and clean
it.
➤ If necessary, contact an autho-
rized service agent to replace
the seal.
➤ Clean the condenser.
➤ Clean the ventilation open-
ings.