F: function programming
xxxx: password
y: desired function from 1 to 5
z: value 0 to z depending on the function
The HAMGSM will send a confirmation message to the programmed GSM number with every function
modification.
AMA2 REV 2.29
PROG=0,2,7,2,3
2.4.2.1. Function 1: Line Test
2.4.2.2. Function 2: AUX Input
2.4.2.3. Function 3: Detector Sensitivity
2.4.2.4. Function 4: Output (white cable for buzzer or external device)
2.4.2.5. Function 5: SMS Counter
HAMGSM_v5
When activated the HAMGSM will start the line test at the set time.
• Send following message to the HAMGSM: Fxxxx1=z. F stands for "FUNCTION", xxxx
stands for the password, 1 stands for the function type, z stands for the line test status (0 =
switched off (default), 1 = every day, 2 = every week, 3 = every month).
Immediate or delayed alarm (NO or NC).
• Send following message to the HAMGSM: Fxxxx2=z. F stands for "FUNCTION", xxxx
stands for the password, 2 stands for the function type, z stands for the status (0 = direct
alarm and NO input connected to the ground, 1 = direct alarm and NC input, 2 = delayed
alarm (15s) and NO input, 3 = delayed alarm (15s) and NC input, 4 = delayed alarm (15s)
and NO input + identification, 5 = delayed alarm (15s) and NC input + identification (2 =
default)).
• For positive control, see section 3.6. Positive Control of the AUX input.
• Send following message to the HAMGSM: Fxxxx3=z. F stands for "FUNCTION", xxxx
stands for the password, 3 stands for the function type, z stands for the status (0 = sensor
switched off, 1 = low sensitivity, 2 to z = decreasing sensitivity to value 9 (value 7 is the
default value)).
• Send following message to the HAMGSM: Fxxxx4=z. F stands for "FUNCTION", xxxx
stands for the password, 4 stands for the function type, z stands for the status.
0: on/off via SMS (ONxxxx: alarm output is high, OFFxxxx: alarm output is low)
1: output follows the ringtone of the GSM. The HAMGSM will act as a remote control with
unlimited range. Call the HAMGSM to activate a relay. The call is free of charge. A 1-
second pulse is sent (+12V).
2: buzzer activated. This is the default setting. The buzzer will be activated in case of a pre-
alarm and when the signal strength is displayed.
Attention: The buzzer functions are deactivated with status 0 and 1 (2 = default).
• Send following message to the HAMGSM: Fxxxx5=z. F stands for "FUNCTION", xxxx
stands for the password, 5 stands for the function type, z stands for the number of