MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse has no
IbL
effect during the opening phase.
Off: condominium function disabled.
The multi-flat function is enabled or disabled during the TCA counting.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter signal has no
ibca
effect during the TCA counting.
Off: the bloc of flat function is disabled.
The rapid closure is enabled or disabled
On: rapid closure is enabled. When the gate is open or moving, the photocell activation causes
SCL
the automatic closure of the gate after 3 s. It is activated only with TCA:ON
Off: rapid closure is disabled.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
Enabled or disables HOLD-TO-RUN function
On: HOLD-TO-RUN function.
htr
The pressure of the OPENS/CLOSES button must be maintained throughout the entire manoeuvre.
The opening of the STOP input stops the motor. All the safety inputs are deactivated.
Off: Automatic/semiautomatic function
PP input as OPEN and PED input as CLOSED are enabled or disabled.
opcl
On: PP input is enabled as OPEN and PED input is enabled as CLOSE.
Off: PP and PED inputs are enabled with their function.
Selects the operating mode of the blinking light during the time TCA
ltca
On: Blinking light on during TCA
Off: Blinking light off during TCA
The operating mode of the PHOT C input is selected.
On: PHOT C input is activated in both opening and closing phases.
In the opening phase: the contact opening causes the motor stop. When the photocell is
released, the motor restarts in the opening phase.
phcl
In closing phase: the contact opening causes the motor stop. When the photocell is released,
the motor inverts the movement direction (open).
Off: The PHOT C input is activated in the closing phase only.
In the closing phase: the contact opening causes the motor stop and the immediate reversion
of the operation direction (open).
Enables or disables checking of photocells on PHOT input, active both in closing and in opening.
On: Check enabled. If the check has a negative result, no manoeuvre is commanded. See Fig.16
TST1
- "PHOTO TEST". (AUX1=3)
Off: Check of photocells each time a manoeuvre is disabled. This setting requires maintenance
of photocells every 6 months.
Enables or disables the check of photocells on PHOT C input.
On: Check enabled. If the check fails, no manoeuvre will be enabled. (AUX1=3)
tst2
Off: Check of photocells each time a manoeuvre is disabled. This setting requires maintenance
of photocells every 6 months.
Enables or disables motors check.
TSTm
On: Check enabled. If the check has a negative result, no manoeuvre is commanded.
Off: Check disabled.
Changing the operating mode of the PHOT OPEN and BAR inputs in the event the sensitive
edges are installed on the mobile opening and closure edges (see Fig.21).
On: The PHOT OPEN input assumes a similar function to the BAR input, but inverts motion for
3s only during the opening phase. The edge connected to the BAR input is only active during
bar
the closure phase.
Off: Intervention of the sensitive edge connected to the BAR input stops movement of the door
and inverts for approx. 3s, both opening and closure.
The PHOT OPEN input re-starts functioning of the photocell active on opening.
The "forced opening in case of power cut-off" function is activated or deactivated (it can be
activated only with connected and operating emergency batteries).
On: Activated function. In the event of power failure, before the emergency battery completely
aopf
discharged, the control unit causes an opening operation.
The barrier remains open until the power supply is back.
Off: Deactivated function.
26
8.4.2) LOGICS (
)
LOG
FUNZIONE
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)