Technical Data - REMS CamScope Instrucciones De Servicio

Ocultar thumbs Ver también para CamScope:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
eng
● Children and persons who, due to their physical, sensory or mental abilities
or lack of experience and knowledge are unable to operate the electrical
device safely may not use the electrical device without supervision or
instruction by a responsible person. Otherwise there is a risk of operating
errors and injuries.
● Only allow trained persons to use the electrical device. Apprentices may only
operate the electrical device when they are older than 16, when this is necessary
for their training and under the supervision of a trained operative.
● Check the power cable of the electrical device and the extension leads
regularly for damage. Have these renewed by qualifi ed experts or an authorised
REMS customer service workshop in case of damage.
● The mains plug of the controller unit (7) connecting cable serves as a
disconnecting device from the power supply circuit. Connect the controller
unit to the power supply circuit so that it is near to the socket and easily
accessible.
Safety instructions for rechargeable batteries/batteries
WARNING
WARNING
Read all safety warnings, instructions, illustrations and specifi cations provided
with this power tool. Failure to follow all instructions listed below may result in
electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
● Use the battery and the power supply/charger only in the specifi ed operating
temperature range.
● Charge the battery of the controller unit (7) only with the power supply/
charger of REMS CamScope, REMS CamScope S. There is a risk of fi re when
an unsuitable charger is used.
● Charge the battery of the controller unit (7) to full capacity with the power
supply/charger before using for the fi rst time to get full battery performance.
Batteries are delivered partly charged.
● Never charge batteries unattended. Battery chargers and batteries can cause
hazards which lead to material damage and/or injury when charged unattended.
● Protect the batteries against heat, sunlight, fi re, moisture and wet. There is
a risk of explosion and fi re.
● Do not use the batteries in areas where there is a risk of explosion and in
the vicinity of infl ammable gases, solvents, dust, fumes, liquids for example.
There is a risk of explosion and fi re.
● Do not open the batteries or modify their construction. There is a risk of
explosion and fi re due to short-circuiting.

1. Technical data

Use for the intended purpose
WARNING
WARNING
The REMS CamScope, REMS CamScope S and REMS CamScope Wi-Fi endoscope cameras are used for the inspection and damage analysis of locations with
diffi cult access such as cavities, shafts, pipes, drains, chimneys etc. and serve for documenting the inspection results in the form of photos and videos, in the REMS
CamScope S and CamScope Wi-Fi in the form of videos with voice recording. All camera cable sets are protected against occasional submersion in water (IP 67).
All other uses are not for the intended purpose and are therefore prohibited.
1.1. Supply format
REMS CamScope
REMS CamScope S
REMS CamScope Wi-Fi
* Supply format:
Handheld unit, 4 batteries 1.5 V, AA, LR6, controller unit, MicroSD-card 8 GB, power supply/charger unit, USB cable, video cable, case
1.2. Article numbers
Camera cable set Color 16-1
Camera cable set Color 16-1 90°
Camera cable set Color 9-1
Camera cable set Color 4.5-1
900 mm push cable extension
REMS CleanM
Set 16-1
175110
* Supply format
Camera cable set Color 16-1
Add-on mirror, add-on hook
Add-on magnet
175130
* Supply format
Camera cable set Color 16-1
Add-on mirror, add-on hook
Add-on magnet
175140
Handheld unit
4 1.5 V, AA, LR6 batteries
Camera cable set Color 16-1
Add-on mirror, add-on hook
Add-on magnet
Operating instructions, case
175103
175106
175104
175102
175105
140119
● Do not use batteries with damaged housings or damaged contacts. Damage
to or improper use of batteries can cause fumes to escape. The fumes can irritate
the respiratory tracts. Let in fresh air and consult a doctor in case of symptoms.
● Avoid contact with leaking batteries. Do not touch the fl uid. Leaking battery
fl uid can cause skin irritation and burns. Rinse off immediately with water in case
of contact. Also consult a doctor if the fl uid gets into the eyes.
● Observe the safety instructions on the battery and the rapid charger.
● Keep unused batteries away from paper clips, coins, keys, nails, screws
or other small metal objects which could cause bridging of the contacts.
There is a risk of explosion and fi re due to short-circuiting.
● Pay attention to the position of the plus and minus poles when inserting
the batteries. There is a risk of explosion and fi re due to short-circuiting.
● Remove the batteries from the handheld unit (5) before longer periods of
inoperation/storage. Protect the battery contacts against short-circuiting, e.g.
with a cap. This reduces the risk of fl uids escaping from the battery.
● Do not throw damaged/empty batteries in the normal household waste.
Hand the damaged/empty batteries over to an authorised REMS contract service
workshop or a recognised disposal company. Observe the national regulations.
● Keep batteries out of reach of children. Batteries can be life threatening if
swallowed, seek medical assistance immediately.
● Take the batteries out of the handheld unit (5) when they are empty. This
reduces the risk of fl uids escaping from the batteries.
● Never recharge the batteries, open them, throw them on fi res or create a
short-circuit. The batteries can cause fi res and burst. There is a risk of injury.
Explanation of symbols
WARNING
WARNING
Danger with a medium degree of risk which could result in
death or severe injury (irreversible) if not heeded.
NOTICE
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating manual before starting
Electrical device complies with protection class II
Environmental friendly disposal
CE conformity mark
Set 9-1
175111
* Supply format
Camera cable set Color 9-1
Add-on mirror, add-on hook
Add-on magnet
175131
* Supply format
Camera cable set Color 9-1
Add-on mirror, add-on hook
Add-on magnet
175141
Handheld unit
4 1.5 V, AA, LR6 batteries
Camera cable set Color 9-1
Add-on mirror, add-on hook
Add-on magnet
Operating instructions, case
eng
Set 4,5-1
175112
* Supply format
Camera cable set Color 4,5-1
175132
* Supply format
Camera cable set Color 4,5-1
175142
Handheld unit
4 1.5 V, AA, LR6 batteries
Camera cable set Color 4,5-1
Operating instruction, case
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Camscope sCamscope wi-fi

Tabla de contenido