- Safety valve (pos. 7 fig. 4b).
- Joint that allows to fix the reducer to the back-plate (pos. 8 fig. 4b).
2.4. Pressure gauge (pos. D fig. 1,2,3 and fig.4a)
Pressure gauge with zero stop feature and within the precision limits of class 1.6. It is equipped with a nickel-plated
casing and covered with a gauge cover shell to protect it from shock. The quadrant is luminous, with a full scale of 360
bar, a resolution of 5 bar and a reserve indicator under 50 bar. A second PSI scale is provided.
2.5. Automatic demand valve with audible warning device (pos. E in fig. 1,2,3 and fig. 5)
The demand valve is made of a reinforced plastic material case and contains both the device that delivers the air and
the acoustic warning device. It is connected to the reducer via a medium pressure hose with an articulated connector.
The button (pos. 1 fig. 3) allows you to block the dispensing device that is activated before the first breath. A type A
or BN demand valve can be provided depending on the full face mask version (see section 2.6).
2.6. Full face mask (Fig. 6)
A description of the masks that can be used with the self-contained breathing apparatus RN series is described here
below. Check the Configurator for details on the masks that can be used on each model .
• Type "A" with positive pressure and thread connector EN 148-3 (M45x3), to be used with Type A demand valve.
Available models:
- TR 82 A (code 112300000) certified according to EN 136:98 class CL3
- TR 2002 A CL3 (code 113000000), TR 2002 S A CL3 (cod. 113060000) certified according to EN 136:98 class 3
- TR 2002 A CL2 (code 113040000) certified according to EN 136:98 class CL2.
- TR 82 A CL3+ (code 11230FR00) certified according to EN 136:98 class CL3+ (flame engulfment test passed, as
required by EN 137:2006)
- TR 2002 A CL3+ (code 11300FR00), certified according to EN 136:98 class CL3+ (flame engulfment test passed, as
required by EN 137:2006)
- TR 82 A E CL3+ (code 112110000) certified according to EN 136:98 in classe CL3+ flame engulfment test passed, as required
by EN 137:2006), equipped with special hooks designed to be connected to fire fighting helmets.
Note: The operation of the SCBA, if equipped with connector EN 148-3, it is still possible with other masks conform to the same
standard exclusively in emergencies and in case it is not available (due to accidents) the correct mask.
• Type "BN" with positive pressure and DIN 58600 bayonet connector, to be used with Type BN demand valve. BN masks
are also provided with a special patented mechanism that enables use with negative pressure devices such as SCBA
demand valves or canisters having a standard thread connector to EN 148-1. (Rd 40x1/7").
Available models:
- TR 2002 BN CL3 (code 113010000), TR 2002 S BN CL3 (code 113070000) certified according to EN 136:98 class 3
- TR 2002 BN CL2 (code 113050000) certified according to EN 136:98 class CL2.
- TR 2002 BN CL3+ (code 11301FR00), certified according to EN 136:98 class CL3+ (flame engulfment test passed, as
required by EN 137:2006)
• Type "B" with positive pressure and DIN 58600 bayonet connector, to be used with Type BN demand valve.
Available models:
- TR 82 B (code 112310000) certified according to EN 136:98 class CL3.
- TR 82 B CL3+ (code 11231FR00) certified EN 136:98 class CL3+ (flame engulfment test passed, as required by EN
137:2006).
- TR 82 B E CL3+ (code 112120000) certified according to EN 136:98 class CL3+ (flame engulfment test passed, as
required by EN 137:2006), equipped with special hooks designed to be connected to fire fighting helmets.
See the attached instructions of each mask for more information on their features and appropriate use.
2.7. Accessories
2.7.1. Four-ways valve
The Automatic 4-way connection or 4-way valves is an accessory provided upon request that allows you to:
- feed a second operator who will be equipped with an individual warning device signal on their mask;
- connect the self-contained breathing apparatus to an alternative source of air to prolong its autonomy and/or to
ensure a safe escape whenever the main feeding source has suffered an accidental interruption. When fed by an
alternative source (at 5.5 bar), the cylinder is automatically excluded.
The detailed instructions for use of the 4-way valve are attached to the accessory (instruction code 960040000).
Pag. 16 / 55