TABLE OF CONTENTS
®
! ...................................................................
Care and Cleaning .....................................................................................
Caution .......................................................................................................
Before Installation ......................................................................................
Tools You Will Need ...................................................................................
Trim Installation ..........................................................................................
Installation Check .......................................................................................
Rough-In......................................................................................................
THANKS FOR CHOOSING TOTO
TOTO's
®
mission is to provide the world with healthy, hygienic and more
comfortable lifestyles. We design every product with the balance of form
and function as a guiding principle. Congratulations on your choice.
CARE AND CLEANING
Your new faucet is designed for years of trouble-free performance. Keep it
looking new by cleaning it periodically with mild soap, rinse thoroughly with
warm water and dry with a clean, soft cloth. Do not use abrasive cleaners,
steel wool or harsh chemicals as these will dull the finish. Failure to follow
these instructions may void your warranty.
CAUTION
!
RISK OF SCALDING: THIS VALVE MUST BE CALIBRATED BY THE
INSTALLER. SEE VALVE CALIBRATION PROCEDURE.
Once calibrated, this valve has a limiter to prevent the temperature from
exceeding 120º F (49º C).
This valve was calibrated at the factory at the following conditions:
Hot: 140º F (60º C) at 14.5 psi (0.1 Mpa)
Cold: 60º F (15º C) at 14.5 psi (0.1 Mpa)
Operating condition:
Minimum Pressure .................7 psi
Maximum Pressure ................108 psi
If the water pressure exceeds 108 psi, use a pressure-reducing valve to reduce
the pressure down to a safe level.
above this temperature will shorten the life of valve or damage the valve and could
result in leaks.
Do not reverse the hot and cold water inlets.
Do not use steam for hot water supply.
Do not disassemble the thermo unit.
®
!
º F (85º C). Using the valve
2
2
2
2
3
3
4
5
6
7
2-3/8"
(6 cm)
(17.0 cm)
ROBINETTERIE
2-3/8"
2-1/2" (6.4 cm) max.
(6 cm)
9-7/8"
3-7/8"
(25 cm)
(10.0 cm)
6-3/4"
2-1/4" (5.7cm) min.
3" (7.6cm) max.
19