Professional Learning Procedure (See Also Pages 8-10) - PRASTEL UNIK2E Manual Técnico De Instalación

Para puertas automáticas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

UNIK2E
V2
4.3

PROFESSIONAL LEARNING PROCEDURE (see also pages 8-10)

Using the professional learning procedure the installer can determine:
d) the instant in which the opening and closing slow-down starts
e) the pedestrian function
f)
the safety device trigger mode.
When the motor and the safety devices are connected, programme the remote controls to be used (see page 8)
with the gate stopped (green LED GC turned on).
Position the
gates half
open
The second leaf then the first leaf close
ATTENTION
: if there are no electric limit
switches or mechanical stop in opening see note
4, point g
MANUAL INTERVENTION TO CHANGE THE FUNCTIONS
Safety intervention
in opening
The "EDG" safety in
opening must:
End of closing
Electric limit switches
or mechanical stop
intervention
Pedestrian function
Will pedestrian
function be used?
NO
YES
only by
wire
Press
together
P1/SET and
P2/RAD
Yellow LED turns off.
End of learning.
RESET:
press and hold the
programming button
P1/SET for 2 seconds
Stop then
Press P1/SET or
invert for 2
remote control
sec.
button 1
Press P2/RAD or
button 2 of the
remote control
Stop then
open when
The gate opens
cleared
NO
Closing slow-
down
When the slow-down is to
start press button 1 of a
remote control for leaf 1
and button 2 for leaf 2.
Press the button of the remote
control that will be used for the
pedestrian function (different from 1)
YES
by radio
+ by wire
Press P1/SET or button 1 of the
remote control
Control unit starts pedestrian
Adjust trimmers if necessary.
ATTENTION
A variation of trimmer "FOR" (speed) requires the repetition
of the learning procedure from RESET
ENGLISH
Yellow LED
flashes
The two leaves briefly open
If motor turns in reverse,
invert wires and start
procedure again from RESET.
Opening slow-
down
When the slow-down is to
start press button 1 of a
remote control for leaf 1 and
button 2 for leaf 2.
Press P1/SET or
remote control
button 1.
YES
Press P2/RAD or
button 2 of the
remote control
The gate closes
opening
7
Within 5 seconds, press
the programming button
P2/RADIO for 1 second
Yellow LED
NO
End of opening
YES
Electric limit switch
or mechanical stop
triggering
Stop then
invert
Stop then
invert when
cleared
Press P1/SET or button 1 of
the remote control to stop
pedestrian opening
Control unit carries out
STOP and re-closing
.
ISUNIK2Ev2_EU_10_12.doc
stays on
Safety
intervention in
closing
Photocell "PHO"
in closing must:

Publicidad