Steinberg SBS-KW-3000 Manual De Usuario página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
ANTI-MOTION
At the cost of measuring time, the Anti-Motion function intelligently settles the
determination of weight when the scale is in motion. The weaker Anti-Motion is,
the faster the scale displays the weight, but the longer it takes to be stable.
Anti-Motion can be set to: 0 (off), 1 (weakest), 2 (weak), 3 (normal), 4 (strong),
5 (strongest).
Press
or
to enter the Anti-motion setting.
Press
or
and
DYNAMIC WEIGHING
In some special application where the scale´s accuracy is not so important as the
scale´s stability for the weight reading, the dynamic weighing can be a useful
function to set the weight reading faster.
Press
or
to enter the Dynamic Weighing setting.
Press
or
and
GRAVITY
This value can be set from 0.000 to 9.999. Only adjust the Gravity when the scale
is used in a place where the acceleration of gravity is greatly different from the
EN
place where it was calibrated.
Press
or
to enter the Gravity setting. G---- shows
Press
or
, and then
to move the digit. Input the Gravity value. Press
USER UNIT
The User Unit can be set from 0.000 to 9.999.
The User Unit is a named unit which is usually used in the user's region, but
which is not included in the scale by default. It is a ratio to the System Unit. For
example, if the User Unit is set to 1.234 and if the System Unit is kg, then after
switching to User Unit, the scale measures the weight (1000kg), and displays the
calculated value (1234usr).
This means you have to watch up the maximal load hanging on the scale while
using the user unit, to not overload the scale because of a different displayed
value!
Press
or
to enter the User Unit setting. U ---- shows
Press
or
, and then
to move the digit. Input the User Unit value. Press
- shows
to change the value.
Y--- shows
to change the value.
to modify the digit. Press
or
to input the decimal point.
to modify the digit. Press
or
to input the decimal point.
31
CALIBRATION
ENTERING CALIBRATION SETTINGS
Press
twice to enter the Password mode.
The scale displays
Press
P8416.
Press
or
SYSTEM UNIT
The Scale displays the System Unit, e.g.,
unit is kg. The System Unit can be set to: kg and lb.
Press
or
Press
or
CALIBRATION GRAVITY
This value can be set from 0.000 to 9.999. The value 9.794 is set by default.
Press
or
Press
to move the digit. Input the Gravity value. Press
, and
MAX. CAP
Do NOT attempt to set Max. Cap. greater than scale's actual capacity. Overloading
causes severe harm to scale, and is very dangerous.
Press
or
Press
to move the digit. Input the max. capacity value. Press
point.
ZERO DETECTION
Press
or
Keep the scale without load and press
12345.
After the detection is finished, the scale automatically enter the Load1 Detection.
LOAD 1 DETECTION
The scale displays
, and
Load a standard weight, and press
Press
or
move the digit. Input weight value. Press
. Press
or
or
, and
, to move the digital. Input the Calibration password:
to confirm the input and to enter Calibration. CAL shows.
to enter the System Unit setting.
, and
, to change the System Unit.
to enter the Gravity setting. G---- shows.
or
, and then
to modify the digit. Press
to enter the Gravity setting. 00000 shows
or
, and then
to modify the digit. Press
to enter the zero detection.
or
.
or
. 00000 shows
, and then
to modify the digit. Press
to input the decimal point.
32
, and
to modify the digital.
, indicating that the system
n--- shows
EN
or
, and
to input the decimal point.
or
, and
to input the decimal
shows.
to display the weight code
or
, and
to

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Sbs-kw-5000

Tabla de contenido