Keep the load stable and press
Wait until the weight code is stable. Press
Once the detection finished, the scale automatically enters Load2 Detection.
LOAD 2 DETECTION
The scale displays
.
Load a standard weight, and press
Press
or
, and then
move the digit. Input weight value. Press
Keep the load stable and press
Wait until the weight code is stable. Press
Once the detection finished, the scale automatically enters Load3 Detection.
LOAD 3 DETECTION
The scale displays
.
Load a standard weight, and press
Press
or
, and then
move the digit. Input weight value. Press
Keep the load stable and press
EN
Wait until the weight code is stable. Press
Once the detection finished, the scale automatically saves and exits the Calibra-
tion mode.

BATTERY MAINTENANCE

To maximize battery life, please read the following battery maintenance
guide.
This scale is powered by a 6V 4.0Ah rechargeable lead-acid battery.
The charging time for a completely discharged battery is approximately 12
hours. When charging the battery, the charging indicator being red indicates
a lack of power, the green indicator indicates full.
Depending on the LED brightness and on the idle mode setting, the battery
works from 60 hours to 200 hours.
In order to conserve battery life, enable Auto-Off and Idle Mode, dim the LED
brightness.
To obtain a maximum service life, the battery should be stored between -20°C
(-4°F) and +50°C (122°F). Stored batteries should be recharged every three
months.
The battery is permanently attached to the battery door. To remove the bat-
tery pack, turn off the two screws on the access door, pull the battery pack
straight out, and unplug the battery cable from the scale.
or
to display the weight code 23456.
or
to start the weight detection.
or
. 00000 shows
to modify the digit. Press
or
, and
to input the decimal point.
or
to display the weight code 34567.
or
to start the weight detection.
or
. 00000 shows
to modify the digit. Press
or
, and
to input the decimal point.
or
to display the weight code 45678.
or
to start the weight detection.
33

TROUBLESHOOTING

Problem
not power-on after
is depressed
to
display flashes
no action taken after
key pressed
weight reading not
stable
to
weight reading not zero
when no load
large error in weight
reading
battery cannot be re-
charged
short remote control-
ling distance
Possible Cause
Suggested Solution
discharged / defective
check battery and charge
battery
press harder and keep
defective
key
pressing 2sec
defective power cable
open front panel, check
power cable
defective mainboard
contact representative
discharged battery
charge battery
scale is disturbed
re-plug power cable
defective key
contact representative
load in motion
keep load stable
weak Anti-Motion
change Anti-Motion level
damped loadcell or main-
dry loadcell or mainboard
board
defective mainboard
contact representative
discharged battery
charge battery
load-cell stressed too long
hang scale in storage
drifting loadcell
contact representative
scale not zeroed before
manual Zero scale before
applying load
loading
wrong unit
switch to correct unit
scale requires calibration
calibrate scale
defective loadcell or main-
contact representative
board
defective charge board
contact representative
defective battery
discharged / defective
replace remote controller
remote battery
batteries