TO GET THE BEST RESULTS AND A HIGHER DURATION OF THE EQUIP-
MENT IT IS ADVISABLE TO READ THOROUGHLY THIS MANUAL BEFORE
OPERATING WITH THE EQUIPMENT.
1- SAFETY INSTRUCTIONS
Read the operating instructions carefully before use the instrument.
Ensure that only trained staff work with the instrument.
Risk of burn
Caution when touching the housing parts and the heating plate. The heating
plate can reach temperatures of 550 ºC.
Pay attention to the residual heat after switching off.
Protective ground contact
Make sure that socket is earthed (protective ground contact) before use.
When work, wear the personal guard to avoid the risk from splashing and eva-
poration of liquids and release of toxic or combustible gases.
Set up the instrument in a spacious area on a stable, clean, non-slip, dry and
fireproof surface, do not operate the instrument in explosive atmospheres, with
hazardous substances or under water.
Gradually increase the speed, reduce the speed if the stirring bar breakaway
because of too high speed and if the instrument is not running smoothly, or it the
container moves on the base plate.
Temperature must always be set to at least 50 ºC lower than the fire point of the
media used.
Beware of hazards due to flammable materials or media with a low boiling
temperature, overfilling of media and unsafe container.
Process pathogenic materials only in closed vessels.
Check the instrument and accessories before handle it for damaged compo-
nent. Safe operation is only guaranteed with the accessories described in the
"Accessories" chapter. Accessories must be securely attached to the device and
cannot come off by themselves. Always disconnect the plug before fitting acces-
sories.
Ensure that the external temperature sensor is inserted in the media to a depth
of at least 20 mm.
When using metal vessels, do not place the temperature sensors on the bottom
of the vessel. Placing sensors on the vessel bottom can cause excessively high
Instruction manual 50694130
ENGLISH
Pag. 14
Version 1 August 2015
14- ACCESSORIES
[1] 90694001
[2] 90694002
[5] 90694306
[6] 90694307
[9] 90694310
Reference
Description
[1] 90694001
Temperature sensor pt1000, l. 230 mm, included
[2] 90694002
Stand kit for sensor pt1000, included
[3] 90694011
Temperature sensor pt1000, with glass coated, l. 230 mm
[4] 90694305
Poly-bloc stand red, 11 holes ø 12,5 mm /width 20 mm / tubes 4 ml
[5] 90694306
Poly-bloc stand purple, 4 holes ø 28 mm / width 24 mm / tubos de 20 ml
[6] 90694307
Poly-bloc stand blue, 4 holes ø 28 mm / width 30 mm / tubos de 30 ml
[7] 90694308
Poly-bloc stand black, 4 holes ø 28 mm / width 43 mm / tubos de 40 ml
[8] 90694309
Poly-bloc stand green, 6 holes ø 17,8 mm / width 26 mm / tubos de 8 ml
[9] 90694310
Poly-bloc stand gold, 4 holes ø 21,6 mm /prof. 31,7 mm / tubos de 16 ml
Instruction manual 50694130
ENGLISH
[3] 90694011
[4] 90694305
[7] 90694308
[8] 90694309
Pag. 23