Produktgruppe 512
31 von 32
Note
PW 6101, PW 6131, PW 6161, PW 6201:
Remove the electrical connection cover on the rear of the machine.
Electrically connect the flow meter in accordance with the MF 07 wiring diagram.
Replace the electrical connection cover on the rear of the machine.
Note
PW 6163, PW 6243, PW 6323:
Remove the cover from the connection box.
Connect the flow meter to the terminal block in accordance with the wiring diagram.
Replace the connection box cover.
Check the newly installed parts for leaks (at the water connection).
Test for correct function.
Reconnect the machine to the electrical supply and the gas supply (if applicable).
Set the activation for the appropriate flow meter (number 1, in this example) via service mode to activate the control.
Service Settings Basic settings Water intake Impeller Impeller 1: No Yes OK (for level Impeller 1: Yes ) Back (go
back one level) Diskette symbol to save the activation for flow meter 1.
Note
For IDs 1000/1001 data must be backed up manually:
Back up data manually via service mode.
Service Backup Backup data for BAE (EW) Overwrite existing data? Diskette symbol to overwrite BAE (EW)
data.
To quit service mode, switch off the machine.
Carry out a functional check, e.g., by starting a wash program. This program should take in water via the appropriate flow meter.
If no fault message appears in the display, then the flow meter is functioning correctly.
Perform a function test, e.g., by starting a wash program. The program should take in water via the appropriate flow meter.
If no fault message appears in the display, then the flow meter is functioning successfully.
am
15.08.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
M.-Nr. 06258812