Produktgruppe 512
58 von 60
Water recycling connection for PW 610x, PW 613x, PW 616x, PW 620x:
Disconnect the machine from the power supply.
Remove the machine lid.
Remove the rear panel.
Remove the mixer box cover plate on the rear of the machine; see Fig. 1.
Loosen the hose clip on the drain hose. Disconnect the drain hose; see Fig. 2.
Drill a 28mm (1.1 ) diameter hole for the water recycling connection; see Fig. 4.
Warning!
Carefully collect and remove all swarf produced by drilling through the mixer box drain hole; see Fig. 2.
Connect the water supply hose with hose clip onto the drilled-out connection stub. Tighten the hose clip; see Fig. 6.
Re-install the mixer box cover and secure the supply hose feed-through flange; see Fig. 7.
Re-install the drain hose on the mixer box and tighten the hose clip.
Water recycling connection for PW 6241, PW 6321:
Disconnect the machine from the power supply.
Remove the machine lid.
Remove the rear panel.
Remove the mixer box cover plate on the rear of the machine.
Pre-assemble the connection hose from the suds container to the connection panel as appropriate. See Fig. 8.
Note
For the PW 6321 the hose must be shortened so that X1 = 80 mm as shown.
The hose to the connection panel, Fig. 8, must be shortened so that X2 = 28.5 mm.
Remove the blanking stopper from the suds container.
In order to secure the holder (Fig. 8, Pos. 1) drill a 6 mm dia. hole in the rear flange of the suds container at a distance of x = 110 mm
from the seam as shown in Fig. 9.
Lay the connection hose in the machine; see Fig. 10
Install the angled connector and holder on the suds container; see Fig. 11.
Pass the cover plate through the opening in the connection panel and install it.
Use a cable tie to secure the connection hose to the water intake hose; see Fig. 12.
Water recycling connection for WS 5101, WS 5141, WS 5191, WS 5240, WS 5320:
Disconnect the machine from the power supply.
Remove the machine lid.
Remove the rear panel.
Remove the mixer box cover from the rear panel.
WS 5101
WS 5141
WS 5191
WS 5240
WS 5320
Table 1: Shortened Hose Lengths
Cut the connection hose between the suds container and connection panel to size depending on the machine model (see Fig. 14
and Table 1).
Remove the seal with the metal washer from the suds container. Reuse the seal.
Fasten the seal and connection hose into the suds container and secure with the M 5 x 12 bolt, washer and M 5 self-locking nut.
See Fig. 15, Pos. 1.
Screw the connection hose stub to the connection panel. See Fig. 15, Pos. 2.
WS 5101/5141: Shorten the imbalance sensor antenna by 45 mm.
16.12.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
X
280
280
340
476
317
Umbau- und Montageanweisung
M.-Nr. 04598534
Y
280
280
203
205
205