5.5

Connection to AC Power

Danger! Risk of electric shock!
B
Do not operate the pump in wet
environment and only under the fol-
lowing conditions:
 Connect only to an earthed outlet
that is properly installed, earthed
and tested.
 Mains voltage and fuse protection
must
correspond
requirement stated in the "Tech-
nical Specications".
 When operated at pools, garden
ponds and similar locations, the
pump must be protected by a
residual current operated device
(RCD, 30 mA) (DIN VDE 0100 -702,
-738
or
equivalent
local regulations). 
We recommend the use of RCD's
as a general precaution for per-
sonal protection.
 When operating the pump out-
doors the electrical connections
must be splash-proof; the con-
nections must not be placed into
water.
 Use only extension cables of suf-
ficient lead cross section (see
"Technical Specifications"). Com-
pletely unroll cable reels.
5.6
Filling the pump and
priming
A
Caution!
After installation, loss of water
or priming of air the pump needs to
be filled with water. Starting the pump
without water causes damage!
Note: 
3
The suction line does not need to
be filled, the pump is self-priming. How-
ever, depending on length and diameter
of the suction line it may take some time
until pressure has built up.
1.
Remove the water filler plug, com-
plete with gasket.
2.
Slowly pour in clear water, until the
pump is filled.
3.
To reduce the time needed for prim-
ing you can also fill the suction line.
4.
Replace the water filler plug, com-
plete with gasket.
5.
Open pressure line (open tap or
spray nozzle) for any air to escape
during priming.
6.
Start pump (see "Operation").
7.
Turn pump OFF when water runs
out steadily.
14

6. Operation

Pump and suction line must be con-
nected and filled (see "Prior to Opera-
tion").
A
Caution!
The pump must not run dry.
Ensure there is always sufficient
pumping medium (water) available.
with
the
If the motor does not start, no pres-
sure is built up or similar effects are
evident, switch the pump OFF – and
try to resolve the fault (see "Trouble
Shooting").
Pump characteristic curve
The pump characteristic curve shows
which pump capacity is possible in
applicable
dependance on the delivery head.
(Pump characteristic curve for 0.5 m
suction head and 1" suction hose.)
(Pump characteristic curve for 0.5 m
suction head and 1" suction hose.)
(Pump characteristic curve for 0.5 m
suction head and 1" suction hose.)
6.1

Commissioning

3
Note:
The pump runs as long as the
ON/OFF switch is switched ON.
1.
Plug power cable in.
2.
Switch pump on with the ON/OFF
switch.
3.
Open pressure line (open tap or
spray nozzle).
4.
Check to see that the water comes
out!
A
Caution!
With a closed pressure line do
not let pump run for more then
10 minutes, otherwise there could be
damage by the water overheating in
the pump.
6.2
Starting a pump with
Hydromat (HWA)
3
Note:
A pump with installed Hydromat is oper-
ational as long as the ON/OFF switch is
turned ON.
The Hydromat
 starts the pump when water is
required (when opening the dis-
charge line the water pressure falls
off to below the cut-in pressure);
P 3300 S
 turns
the
10 seconds after closing the dis-
charge
increases in the closed discharge
line);
 turns the pump off to prevent dry
running when no water is pumped
(air in suction line).
20
21
22
20 Power indicator (green)
21 Pump indicator (white)
22 Reset button