13
SUPPLEMENTARY INSTRUCTIONS FOR SAFE
DISASSEMBLY OR DISPOSAL
13.1
Most Warnings Same As For Maintenance
Most warnings are the same as those in Supplementary Instructions
for Safe Maintenance, Servicing, and Emergency Repair, in paragraph
12, above. Additions and modifications are described below.
13.2
General
13.2.1
Dead Circuits
Power must be disconnected and testing performed to ensure that no
explosive gas mixtures are present during disassembly and/or
disposal
13.2.2
Disposal Issues
Refer to Process Monitoring System Installation and Startup Manual
for disposal instructions (WEEE considerations).
13.3
Sensor Band
13.3.1
Damaged Sensor Bands
The sensor band should be removed from service and taken out of the
hazardous area if it has mechanical damage. The damaged sensor
band must be handled as a potentially incendive device even when it
is disconnected from a power source. The damaged sensor band
should not be handled in or transported through any areas where
explosive gas mixtures may be present.
13.3.2
Undamaged Sensor Bands
Handle the band carefully to avoid damaging it (no sharp bend radii
and avoid actively flexing it or allowing it to be bumped during
transport). If there is any doubt about whether the sensor band might
be damaged, follow the handling and transport procedures for
damaged sensor bands, above. The original packing foam mandrel
packing material should be used for storage. Do not store the sensor
band in a hazardous area.
20909-01C Rev 06